首页> 外文期刊>Expert review of medical devices >A systematic review of standardized methods for assessment of endograft sealing on computed tomography angiography post-endovascular aortic repair, and its influence on endograft-associated complications
【24h】

A systematic review of standardized methods for assessment of endograft sealing on computed tomography angiography post-endovascular aortic repair, and its influence on endograft-associated complications

机译:对血管内血管造影后血管血管造影后内血症血管造影评估的标准化方法的系统综述及其对内血症相关并发症的影响

获取原文
获取原文并翻译 | 示例
           

摘要

ABSTRACT Introduction: Although there is much attention for proper sizing of pre-operative anatomy before (thoracic) endovascular aneurysm repair ([T]EVAR), standardized assessment of endograft position and apposition at postoperative imaging is seldom addressed in the international guidelines. The highly detailed three-dimensiohal computed tomography angiography (CTA) volumes contain valuable information about the apposition of the endograft with the arterial wall and the position of the device relative to anatomical landmarks in the proximal and distal landing zones, which is currently hardly used. With proper assessment on CTA of the endograft after EVAR, the risk for future endograft-related complications may be determined, allowing patient-tailored, risk-stratified surveillance. Areas covered: This systematic review identified three standardized methods for assessing apposition or position of the endograft in the proximal or distal landing zone on CTA after (T)EVAR. Quantification of apposition and position, validation of measurement precision, and association with endograft-related complications were extracted. Short (<10 mm apposition length) and decreasing (>0 mm) apposition were associated with endograft-associated complications. Expert commentary: Standardized assessment of apposition and position of the endograft in the proximal and distal landing zones on CTA should be incorporated in post-(T)EVAR surveillance. A risk-stratified CTA surveillance protocol is proposed.
机译:摘要介绍:虽然在血管内的血管内麻风瘤修复(胸腔)前血管内解剖学的适当尺寸很大程度上,但在术后术后成像的标准化评估很少在国际指南中解决。高度详细的三维计算断层造影血管造影(CTA)体积包含关于内血填充物与动脉壁的与动脉壁的位置的有价值的信息,以及目前难以使用的近端和远端着陆区的解剖标记的装置的位置。在Evar后对内切拉移植的CTA进行适当的评估,可以确定未来内血症相关并发症的风险,允许患者量身定制的风险分层监测。所涵盖的区域:该系统审查确定了三种标准化方法,用于评估(T)EVAR之后的CTA上近端或远端着陆区内的内血血移植物的环容或位置。提取了定量的定性和位置,测量精度验证以及与内血血移植相关的并发症的关联。短(<10mm的链接长度)和降低(> 0 mm)的宿主与内血症相关的并发症有关。专家评论:CTA上近端和远端着陆区的近端和远端着陆区中的对接和位置的标准化评估应纳入(T)EVAR监测后。提出了一种风险分层的CTA监测方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号