首页> 外文期刊>European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society >Evaluation of a new apparatus combining a mobile device and hand-held roller for the detection of spinal deformities: association with the sum of the right and left angles of trunk inclination
【24h】

Evaluation of a new apparatus combining a mobile device and hand-held roller for the detection of spinal deformities: association with the sum of the right and left angles of trunk inclination

机译:评估组合移动设备和手持辊的新装置,用于检测脊柱畸形:与行李箱倾斜右侧和左角的关系相关联

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose To investigate the intra- and inter-observer reliabilities of the newly developed i-Scolioroller for scoliosis screening, and to determine the optimal i-Scolioroller measurement cutoff values for identifying adolescent scoliosis with a Cobb angle >= 20 degrees. Methods The i-Scolioroller displays the right- and left-side maximum inclination angle (Rmax, Lmax) during the forward bending test (FBT), as well as the angle of trunk inclination (ATI, i.e., whether the Rmax or Lmax is greater). Sum-ATI is defined as the sum of Rmax and Lmax. Intra-class correlation coefficients (ICC) of the ATI and sum-ATI measurements were calculated to analyze the intra- and inter-observer reliabilities for 10 plaster torsos in FBT positions obtained from patients with idiopathic scoliosis. The optimal cutoff values for scoliosis were determined using receiver operating characteristic (ROC) analysis of i-Scolioroller measurements versus Cobb angles obtained from the upright whole-spine radiographs of 112 adolescent outpatients. Results The intra-observer ICCs for the ATI/sum-ATI for 3 observers were 0.851/0.856, 0.786/0.900, and 0.772/0.796, respectively, while the corresponding inter-observer ICCs for all participants were 0.733/0.745. On ROC analysis, an ATI of 8 degrees was the optimal cutoff value for scoliosis (sensitivity and specificity: 79.2% and 70.0%, respectively). The optimal cutoff value for sum-ATI was 11 degrees (sensitivity and specificity: 86.1% and 82.5%, respectively). The areas under the ROC curves were 0.859 for ATI and 0.908 for sum-ATI. Conclusion The optimal cutoff values for identifying scoliosis using the i-Scolioroller were a combination of 11 degrees for the sum-ATI and 8 degrees for the ATI.
机译:目的是调查新开发的I-Scolioroller用于脊柱侧凸筛查的观察者和观察者间可靠性,并确定用于鉴定具有COBB角度> = 20度的青少年脊柱侧凸的最佳I-Scolioroller测量截止值。方法I-ScolioRoler在正向弯曲测试(FBT)期间显示右侧和左侧最大倾角(Rmax,Lmax),以及横延倾角(ATI,即Rmax或Lmax更大的角度)。 SUM-ATI被定义为RMAX和LMAX的总和。计算ATI和SUM-ATI测量的类内相关系数(ICC),以分析从特发性脊柱侧凸患者获得的FBT位置中的10个膏药躯干的内部和观察者间可靠性。使用从112个青少年门诊的直立全脊X射线照片获得的I-Scolioroller测量的接收器操作特性(ROC)分析来确定脊柱侧凸的最佳截止值。结果3个观察者的ATI / SUM-ATI的观察者内部ICC分别为0.851 / 0.856,0.786 / 0.900和0.772 / 0.796,而所有参与者的相应观察员ICCS分别为0.733 / 0.745。关于ROC分析,8度的ATI是脊柱侧凸的最佳截止值(敏感性和特异性:79.2%和70.0%)。 SUM-ATI的最佳截止值为11度(敏感性和特异性:86.1%和82.5%)。 ROC曲线下的区域为ATI和0.908的0.859,用于SUM-ATI。结论使用I-ScolioRoler鉴定脊柱侧凸的最佳截止值是总和ATI和ATI 8度的11度的组合。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号