...
首页> 外文期刊>European Journal of Radiology >Real-time two-dimensional Shear-wave elastography for liver stiffness in children: Interobserver variation and effect of breathing technique
【24h】

Real-time two-dimensional Shear-wave elastography for liver stiffness in children: Interobserver variation and effect of breathing technique

机译:儿童肝硬化的实时二维剪切波形弹性术:Interobserver变化和呼吸技术的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Abstract Objectives To evaluate interobserver variation and to assess the effect of the breathing technique on liver stiffness (LS) measurement using real-time two-dimensional shear-wave elastography (2D-SWE) in children. Methods Patients who underwent real-time 2D-SWE by two operators (group 1) and patients who underwent real-time 2D-SWE by one operator using the free-breathing and breath-holding techniques (group 2) were included. In group 1, interobserver agreement was assessed using the intraclass correlation coefficient (ICC) and the 95% limits-of-agreement was analyzed to evaluate the maximum change in the LS values based on Bland-Altman analysis. In group 2, the Bland-Altman plot and the paired t -test were used to determine the effect of breathing technique on LS measurement. Results The interobserver agreement of the LS measurement in group 1 (n=63) was excellent (ICC, 0.953), and the 95% limits-of-agreement was 31.8% of the mean LS values. In group 2 (n=45), the free-breathing technique revealed systematically lower LS with a mean difference of ?11.1% of the mean LS values, compared to the breath-holding technique ( P =0.016). Conclusion LS measurement assessed by real-time 2D-SWE in children showed excellent interobserver agreement. Changes in LS values less than 31.8% of the mean LS values may represent the measurement error. The free-breathing technique showed lower LS values, compared to the breath-holding technique.
机译:摘要目的是评估interobserver变异的措施,并评估呼吸技术对儿童实时二维剪切波弹性摄影(2D-SWE)的肝硬化(LS)测量的影响。方法采用两种运营商(第1组)和使用自由呼吸和呼吸持有技术(第2组)进行实时2D-SWE的患者进行实时2D-SWE的患者和接受一次操作员的实时2D-SWE的患者。在第1组中,使用Interacllass相关系数(ICC)评估Interobserver协议,分析了95%的协议限制,以评估基于Bland-Altman分析的LS值的最大变化。在第2组中,使用Bland-Altman图和配对T -Test来确定呼吸技术对LS测量的影响。结果1(N = 63)中LS测量的Interobserver协议是优秀的(ICC,0.953),而且达到95%的协议限额为平均值的31.8%。在第2组(n = 45)中,与呼吸保持技术相比,自由呼吸技术系统地揭示了平均值的平均差的平均值Δ11.1%(P = 0.016)。结论儿童实时2D-SWE评估的LS测量显示出优秀的Interobserver协议。 LS值的变化小于平均值值的31.8%可以表示测量误差。与呼吸保持技术相比,自由呼吸技术显示出LS值下降。

著录项

  • 来源
    《European Journal of Radiology》 |2017年第2017期|共6页
  • 作者单位

    Department of Radiology and Research Institute of Radiology Asan Medical Center University of;

    Department of Radiology and Research Institute of Radiology Asan Medical Center University of;

    Department of Radiology and Research Institute of Radiology Asan Medical Center University of;

    Department of Radiology and Research Institute of Radiology Asan Medical Center University of;

    Department of Radiology and Research Institute of Radiology Asan Medical Center University of;

    Department of Radiology and Research Institute of Radiology Asan Medical Center University of;

    Department of Pediatrics Asan Medical Center Children's Hospital University of Ulsan College of;

    Department of Pediatrics Asan Medical Center Children's Hospital University of Ulsan College of;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 放射医学;
  • 关键词

    Ultrasound; Elastography; Liver; Reproducibility; Children;

    机译:超声波;弹性成像;肝脏;再现性;儿童;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号