Investigations were carried out on standardization of X-ray radiography methodology for the detection of hidden insect infestation of berfruit borer, Meridarchisscyrod.es Meyrick. Studies revealed that high voltages are required for the deterction ofhidden insect infestation in ber fruits due to their high amounts of water, which restricts the passage of X-rays through fruits. Among the two hundred combinations the exposure of ber fruits to X-ray radiation of 32 kilovoltage and 9 milliampere for 12seconds was selected as the best combination for ber. Whereas the other combinations 22kilovoltage and 5 milliampere for 8 seconds, 28 kilo voltage and 6 milliampere for 10 seconds and 30 kilovoltage 8 milliampere for 10 seconds manifested into lighter images.
机译:对X射线射线照相方法的标准化进行调查,用于检测Berfruit Borer,MeridarchissCyrod.es Meyrick的隐藏虫害。 研究表明,由于它们的大量水,在BER水果中的虫害排放需要高电压,这限制了X射线通过水果的通过。 在两百个组合中,BER果实的暴露于32千伏辐射和12毫安12秒的12秒被选为BER的最佳组合。 虽然其他组合22kilovoltage和5毫安8秒钟,28公斤电压和6毫安10秒和30千伏电压8毫安8毫安,但表现为更轻的图像。