This paper presents an investigation of a failure of the 316L stainless steel electric-heater tube in a heat-storage tank. Visual examination was performed to discover the characteristics of the fracture zone. The fracture appearance and the ingredient analysis of the filler material were examined using scanning electron microscopy and X-ray diffraction. Also, the region that is susceptible to corrosion was identified using an electrochemical method. From those investigations, the surface defects that were caused by improper die finish during drawing process acted as the initiation points of the corrosion process. The influent water changes the filler material from magnesia to magnesium hydroxide, which causes the volume expansion. The failure of tube occurred due to the combination of the pitting corrosion on the external surface and internal pressure from the volume expansion of the filler.
机译:本文介绍了储热罐中316L不锈钢电加热器管失效的研究。 进行视觉检查以发现骨折区的特征。 使用扫描电子显微镜和X射线衍射检查骨折外观和填料材料的成分分析。 而且,使用电化学方法鉴定易受腐蚀的区域。 从那些调查中,在拉伸过程中造成不当芯片表面造成的表面缺陷作为腐蚀过程的起始点。 进水水将富含氧化镁的填料材料改变为氢氧化镁,这导致体积膨胀。 由于填料的容积膨胀,管腐蚀与内部压力的组合,管的发生故障是由于从填料的体积膨胀的组合而发生。