首页> 外文期刊>Engineering failure analysis >Failure analysis on abnormal corrosion of economizer tubes in a waste heat boiler
【24h】

Failure analysis on abnormal corrosion of economizer tubes in a waste heat boiler

机译:废热锅炉中经济型管异常腐蚀的故障分析

获取原文
获取原文并翻译 | 示例
           

摘要

Repeated shell side corrosion occurred on economizer tubes of a waste heat boiler. In order to find out the root cause of the corrosion, a series of characterization methods were conducted. First of all, the tubes were proved to be qualified A106 Gr. A steel in chemical compositions and metallographic structures. Then, both macroscopic and microscopic characteristics of the failed tube were observed thoroughly. After that, phase compositions of the deposits collected from failed tubes were analyzed. Content of sulfur and nitrogen of deposits was determined precisely as well. The results revealed that repeated failures were primarily owing to sulfuric acid dew point corrosion and the sulfur mainly came from waste liquid of methyl methacrylate (MMA). Finally, mechanisms of the failure were discussed in detail and practical countermeasures were put forward. (C) 2016 Elsevier Ltd. All rights reserved.
机译:在废热锅炉的节能管上发生反复壳侧腐蚀。 为了找出腐蚀的根本原因,进行了一系列表征方法。 首先,证明管是合格的A106 GR。 化学成分和金相结构中的钢。 然后,彻底观察到失败管的宏观和微观特性。 之后,分析了从出血管收集的沉积物的相组合物被分析。 也精确地确定沉积物的硫和氮的含量。 结果表明,由于硫酸露点腐蚀,硫主要来自甲基丙烯酸甲酯(MMA)的废液。 最后,详细讨论了失败机制,提出了实际对策。 (c)2016 Elsevier Ltd.保留所有权利。