The failure mechanism of the fractured droppers used in power supply systems for subway was analyzed with various technologies. Collected evidences indicated that the droppers fracture due to fatigue crack propagation. The chemical composition and mechanical properties of the dropper material were both complied with the normal 304 stainless steel standard. The metallographic examination showed that the microstructure of the failed dropper was normal. The initial region of the fatigue damage was located at a notch near the bending place. Under the cyclic loads caused by the up and downs of the dropper when the train passes by, the crack initiated, propagated and ruptured finally. Results of finite element simulations suggested that the residual force of the droppers will increase as the chamfering radius is. Improving the manufacturing tool was an effective way to reduce the stress concentration and to increase the residual force of the droppers, thus, to improve the service life of the droppers.
机译:用各种技术分析了地铁供电系统中使用的破裂滴落器的破坏机制。收集的证据表明,由于疲劳裂纹繁殖引起的滴注器断裂。滴管材料的化学成分和机械性能均符合正常的304不锈钢标准。金相检查表明,失调滴管的微观结构是正常的。疲劳损坏的初始区域位于弯曲地点附近的凹口处。在火车通过时由滴管的上下和下降引起的循环载荷下,最终发起,传播和破裂的裂缝。有限元模拟的结果表明,随着倒角半径的,滴落器的残余力将增加。改善制造工具是降低应力集中的有效方法,从而提高液滴的残余力,从而提高滴注器的使用寿命。

著录项

  • 来源
    《Engineering failure analysis》 |2020年第1期|共7页
  • 作者单位

    Qilu Univ Technol Shandong Acad Sci Shandong Anal &

    Test Ctr Engn Res Ctr Failure Anal &

    Safety Assessment Jinan 250014 Peoples R China;

    Qilu Univ Technol Shandong Acad Sci Shandong Anal &

    Test Ctr Engn Res Ctr Failure Anal &

    Safety Assessment Jinan 250014 Peoples R China;

    Qilu Univ Technol Shandong Acad Sci Shandong Anal &

    Test Ctr Engn Res Ctr Failure Anal &

    Safety Assessment Jinan 250014 Peoples R China;

    Qilu Univ Technol Shandong Acad Sci Shandong Anal &

    Test Ctr Engn Res Ctr Failure Anal &

    Safety Assessment Jinan 250014 Peoples R China;

    Qilu Univ Technol Shandong Acad Sci Shandong Anal &

    Test Ctr Engn Res Ctr Failure Anal &

    Safety Assessment Jinan 250014 Peoples R China;

    Qilu Univ Technol Shandong Acad Sci Shandong Anal &

    Test Ctr Engn Res Ctr Failure Anal &

    Safety Assessment Jinan 250014 Peoples R China;

    Shandong Jiaotong Univ Traff Judicial Identificat Ctr Jinan 250100 Peoples R China;

    Shandong Jiaotong Univ Traff Judicial Identificat Ctr Jinan 250100 Peoples R China;

    Lille Univ Civil Engn &

    Geoenvironm Lab ULR 4515 LGCgE F-59000 Lille France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工程力学;
  • 关键词

    Dropper; Fatigue; Fracture; Stainless steel wire; Finite element analysis;