首页> 外文期刊>Investigative radiology >Diffusion Tensor Imaging of Healthy Skeletal Muscles A Comparison Between 7 T and 3 T
【24h】

Diffusion Tensor Imaging of Healthy Skeletal Muscles A Comparison Between 7 T and 3 T

机译:扩散张量成像健康骨骼肌肌肉的比较7t和3 t之间的比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objective The aim of this study was to assess and compare the overall performance, reliability, variability, as well as the accuracy of diffusion tensor imaging (DTI) and fiber tracking metrics, for the muscles of the calf at 3 T and 7 T. Materials and Methods Ten volunteers (5 males; mean age, 29.1 +/- 4.7 years), with no history of muscle disease, were examined twice at 3 T and 7 T, using a stimulated-echo acquisition mode DTI sequence. Signal-to-noise ratio (SNR) and DTI metrics (track numbers [tr(n)], length [tr(l)], volume [tr(v)], fractional anisotropy [FA], mean [MD], axial [AD], and radial diffusivity [RD]) of the whole-calf muscles, the tibialis anterior, the gastrocnemius medialis, the gastrocnemius lateralis, and the soleus were collected. The Student t test was used to compare SNR and DTI metrics obtained at 3 T and 7 T. The coefficients of variation and the intraclass correlation coefficients were derived to assess the variability and the reliability of the DTI measurements at 3 T and 7 T. To further assess the accuracy of the measurements, the absolute difference was computed for each DTI metric at 3 T and 7 T and then compared (Student t test). The applied level of significance for all the statistical analyses was P 0.05. Results As expected, the SNR was higher at 7 T than at 3 T (+111%; P 0.001). At 7 T, the tracked fibers of the whole calf muscles, the gastrocnemii, and the soleus were more numerous (tr(n) +5.5%, +3.1%, +8.5%, and +15.1%, respectively), longer (tr(l) +13.1%, +18.8%, +19.3%, and +33.3%, respectively), and showed a greater volume (tr(v) +12.1%, +12.2%, +14.7%, and +15.7%, respectively) than at 3 T (P 0.05 each). The soleus demonstrated higher FA (+14.3%), lower MD (-1.7%), AD (-1.9%), and RD (-2%) at 7 T than at 3 T (P 0.05 each), whereas the other muscles showed more heterogeneous results. The coefficients of variation were good (ie, 10%) for all DTI metrics at both 3 T and 7 T. The intraclass correlation coefficient was excellent (0.750) at 7 T and 3 T for several DTI metrics, such as the tr(n) of the gastrocnemii and the soleus, the tr(v) of the gastrocnemii, the FA of the whole-calf muscles, gastrocnemius medialis, tibialis anterior, and soleus, and the RD of all investigated muscles (ie, whole-calf muscles, gastrocnemii, tibialis anterior, and soleus). There were no significant differences between the 2 consecutive measurements with each device, except for the tr(n) of the whole-calf muscles and the FA of the gastrocnemius lateralis (higher mean absolute difference at 3 T and 7 T, respectively; P 0.05 each). Conclusions Despite the numerous challenges associated with DTI of the muscles, both 3 T and 7 T demonstrated reliable and precise results.
机译:目的本研究的目的是评估和比较整体性能,可靠性,可变性以及扩散张量成像(DTI)和纤维跟踪度量的准确性,用于3T和7 T.材料的小腿肌肉方法10志愿者(5名男性;平均年龄,29.1 +/- 4.7岁),在3T和7 T中没有肌肉疾病的历史,使用刺激回波采集模式DTI序列。信噪比(SNR)和DTI指标(轨道数字[TR(N)],长度[TR(L)],体积[TR(V)],分数各向异性[FA],平均值[MD],轴向收集了全小牛肌的[Ad]和径向扩散率[Rd]),胫骨前,胃肠肿瘤中,腓肠肌外侧,肠胃肠道和单独。学生T检验用于比较在3T和7T处获得的SNR和DTI度量。得出的变异系数和脑内相关系数的系数评估了3 T和7 T的DTI测量的可变性和可靠性。进一步评估测量的准确性,针对3T和7 T的每个DTI度量计算绝对差异,然后进行比较(学生T测试)。所有统计分析的应用程度的显着性是p& 0.05。结果如预期的,SNR高于7吨,比3t(+ 111%; P <0.001)更高。在7吨,整个小牛肌的履带纤维,胃肠炎血症和单独的纤维更加多(Tr(n)+ 5.5%,+ 3.1%,+ 8.5%,+ 15.1%),更长(tr (L)+ 13.1%,+ 18.8%,+ 19.3%,分别为+ 33.3%),显示出更大的体积(Tr(V)+ 12.1%,+ 12.2%,+ 14.7%,+ 15.7%,分别在3℃(每个0.05)。 Soleus在7t至3t时显示出更高的FA(+ 14.3%),低MD(-1.7%),Ad(-1.7%),Ad(-1.9%)和Rd(-2%)(P <0.05),而其他肌肉显示出更异质的结果。对于3T和7 T的所有DTI度量,变异系数是良好的(即,10%)。对于几个DTI度量,腹部相关系数优异(& 0.750)优异(& 0.750)。 Gastrocnemii的Tr(n)和Soleus,Gastrocnemii的TR(v),全小牛肌的Fa,胃肠肿瘤,胫骨前肌肉,胫骨前和单独,以及所有调查肌肉的Rd(即整体) -CALF肌肉,胃肠内血,胫骨前和单独的)。每种装置的连续测量与全小牛肌的TR(n)和胃肠杆菌的FA(分别在3 t和7 t处的平均绝对差异高)之间没有显着差异.P&lt ; 0.05))。结论尽管与肌肉的DTI有多挑战,但3 T和7 T都证明了可靠和精确的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号