首页> 外文期刊>International ophthalmology >Comparison of the PlusOptix S09 and Spot Vision photorefractor to cycloretinoscopy
【24h】

Comparison of the PlusOptix S09 and Spot Vision photorefractor to cycloretinoscopy

机译:PlusOptix S09和Spot Vision Photorefractors对环胞镜的比较

获取原文
获取原文并翻译 | 示例

摘要

Purpose The purpose of this study was to compare refraction measurements for children with the PlusOptix S09 and Spot Vision with cycloplegic retinoscopy. Methods One hundred thirty-six eyes of 68 children (26 boys and 42 girls) were evaluated prospectively. The subjects were separated into two groups. Group 1 comprised the subjects age between 5 and 9 years. Group 2 comprised the subjects age between 10 and 18 years. Photorefraction with PlusOptix S09, photorefraction with Spot Vision and cycloplegic retino-scopy were performed in each patient. Spherical equivalents, spherical power, cylindrical power and axis values were compared between three methods. Results The mean age of the patients was 7.12 ± 1.5 years in group 1 and 12.24 ± 1.8 years in group 2. Spherical equivalent and spherical power measured with PlusOptix S09 were statistically smaller than measured with cycloplegic retinoscopy for group 1 (p = 0.001, p = 0.001) and for group 2 (p = 0.000, p = 0.000). The mean cylindrical power measured with PlusOptix S09 was not statistically different compared to cycloplegic retinoscopy for both groups (p = 0.314, p = 0.05). Spherical equivalents measured with Spot Vision were statistically smaller than measured with cycloplegic retinoscopy for both groups (p = 0.000, p = 0.012). Spherical power measured with Spot Vision was statistically smaller than measured with cycloplegic retinoscopy for group 1 (p = 0.000), but the difference was not statistically significant for group 2 (p = 0.084). The mean cylindrical power measured with Spot Vision was statistically higher than cycloplegic retinoscopy for both groups (p = 0.000, p = 0.012). Conclusions PlusOptix S09 and Spot Vision devices give acceptable results for screening, but prescription of spectacles should not be made according to PlusOptix S09 or Spot Vision devices alone.
机译:目的本研究的目的是将儿童的折射测量与Plusoptix S09和束缚视觉镜检查进行比较。方法预期评估了68名儿童(26名男孩和42名女孩)的一百三十六只眼睛。将受试者分成两组。第1组包括5至9岁之间的受试者。第2组包括10至18岁之间的受试者。用PlusOptix S09进行光反弹,在每位患者中进行斑点视觉和束颈椎视网膜的光反弹。在三种方法之间比较了球形等同物,球形电力,圆柱形功率和轴值。结果患者的平均年龄在1和12.24±1.5岁的组中为7.12±1.5岁。使用Plusoptix S09测量的球形等效物和球形功率与组1组的Cycloplegic视网膜镜测量(p = 0.001,p = 0.001)和第2组(p = 0.000,p = 0.000)。与两个组的束颈视网膜镜检查相比,用Pricoptix S09测量的平均圆柱功率没有统计学不同(P = 0.314,P = 0.05)。用点视觉测量的球形当量统计学上小于两组的Cycleckgic视网膜镜测量(P = 0.000,P = 0.012)。用斑点视觉测量的球形功率比用束颈视网膜镜测量的统计学尺寸为1(p = 0.000),但差异对于第2组没有统计学意义(P = 0.084)。用斑点视觉测量的平均圆柱形功率统计学上高于两个基团的循环视网膜镜检查(P = 0.000,P = 0.012)。结论PLUSOPTIX S09和SPOT VISION器件为筛选提供可接受的结果,但不应仅根据PLUSOPTIX S09或SPOT视觉设备进行眼镜的处方。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号