首页> 外文期刊>BJU international >A novel midstream urine-collection device reduces contamination rates in urine cultures amongst women.
【24h】

A novel midstream urine-collection device reduces contamination rates in urine cultures amongst women.

机译:一种新颖的中游尿液收集装置可降低女性尿液培养物中的污染率。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE To evaluate a novel urine-collection device (UCD) that automatically collects a midstream urine (MSU) sample, and compare contamination rates to those of the conventional MSU sampling method, as the contamination of urine samples for microbiological analysis in women leads to diagnostic ambiguity and unnecessary costs, and may result in part from an incorrect collection procedure. PATIENTS AND METHODS In all, 2823 women from four centres, most from antenatal clinics, were randomized to two urine-collection methods: conventional MSU collection and collection with a novel MSU UCD (the Whiz((R)), JBOL Ltd, Oxford, UK). Semi-quantitative growth and user acceptability were compared between the collection methods. RESULTS MSU samples collected with the UCD had significantly fewer mixed growth samples (9% vs 14%, P = 0.001; 36% relative reduction), significantly fewer heavy mixed growth samples (1.2% vs 3.0%, P = 0.004; 60% relative reduction) and required significantly fewer re-tests (11% vs 16%, P= 0.002; 31% relative reduction). There were more samples with clinically insignificant growth than the conventional MSU group (86% vs 82%, P = 0.005). Those using the UCD preferred it to the conventional method (67.5%) and experienced significantly less spillage during sample collection (27% vs 46%, P = 0.001; relative reduction 41%). CONCLUSION The UCD reduced contamination rates in urine samples and improved the predictive value of the urine culture in a manner acceptable to patients and staff.
机译:目的评估一种新型的尿液收集装置(UCD),该装置可自动收集中游尿液(MSU)样品,并将污染率与传统的MSU采样方法进行比较,因为妇女进行微生物学分析的尿液样品的污染可导致诊断含糊不清和不必要的成本,并且可能部分是由于不正确的收集程序造成的。患者和方法总共将来自四个中心(大部分来自产前诊所)的2823名妇女随机分配到两种尿液收集方法:常规MSU收集和新型MSU UCD(Whiz(R),JBOL Ltd,牛津,英国)。在收集方法之间比较了半定量增长和用户可接受性。结果用UCD收集的MSU样品的混合生长样品数量显着减少(9%比14%,P = 0.001;相对降低36%),重混合生长样品数量显着更少(1.2%vs 3.0%,P = 0.004;相对60%减少),并且所需的重测次数明显减少(11%比16%,P = 0.002;相对减少31%)。与常规MSU组相比,临床上无明显增长的样本更多(86%比82%,P = 0.005)。使用UCD的人比传统方法更喜欢(67.5%),并且在样品收集过程中泄漏少得多(27%比46%,P = 0.001;相对减少41%)。结论UCD以患者和医护人员可接受的方式降低了尿液样本中的污染率并提高了尿液培养的预测价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号