Air Source Heat Pump Water Heaters (ASHPWHs) are efficient and fast-developing sanitary hot water production systems for the building sector. However, it was shown that their energy performance can still be improved. Therefore, a dynamic grey box Modelica based model is developed representing a split type ASHPWH with a mantle heat exchanger. The thermal storage model includes a zonal model to model convection during heat-ups and the heat pump is modeled using the TIL?thermal component library. The model is first compared to dynamic experimental data during 9 heat-up tests under various operating conditions, including low temperature defrosting stages. On such heating periods, the overall mean relative error reached is of 2% for the COP and the maximum temperature error over the height of the tank is less than 1?°C. The model is reproducible and can be used to conduct further design based optimization studies.
机译:空气源热泵热水器(ASHPWHS)是建筑业的高效且快速发展的卫生热水生产系统。 但是,结果表明它们的能量性能仍然可以得到改善。 因此,开发了基于动态灰盒式模型的模型,其代表与地幔热交换器的分体式ASHPWH。 热存储模型包括在散热期间与模型对流进行模型对流的区域模型,并且使用TIL的热泵进行建模。 该模型首先与在各种操作条件下的9个加热测试期间的动态实验数据相比,包括低温除霜阶段。 在这种加热时段,达到的总体平均相对误差为COP的2%,罐的高度上的最大温度误差小于1Ω·℃。 该模型可再现,可用于进行进一步的基于设计的优化研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号