首页> 外文期刊>International journal of laboratory hematology >Establishing a reference range for thromboelastograph parameters in the neonatal period
【24h】

Establishing a reference range for thromboelastograph parameters in the neonatal period

机译:建立新生儿时期血栓弹性仪参数的参考范围

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract Introduction Acquired coagulation disorders are a common cause of neonatal bleeding. The thromboelastograph (TEG) comprehensively assesses haemostatic processes in the body. Unfortunately, the reference range of TEG parameters in the neonatal period has not yet been evaluated, which limits the use of the TEG in neonates. In this study, we aimed to establish the reference range of TEG parameters for the neonatal period. Methods This study included 371 full‐term infants (≥37?weeks of gestation), and we divided these infants into three groups according to age as follows: 1, 2‐7 and 8‐28?days. We measured their peripheral blood using TEG, coagulation routine and platelet count tests. We analysed differences among the groups. Results The reference ranges for TEG parameters are presented as medians and reference ranges (2.5th and 97.5th percentiles) as follows: R (clot reaction time, seconds) 4.80 (2.80‐7.17), Angle (fibrin production rate) 69.90 (44.91‐78.89), K (clot kinetics, min) 1.40 (0.80‐4.50), MA (maximum amplitude, mm) 63.50(44.34‐74.66) and LY30 (lysis at 30?minutes, %) 0.10 (0.10‐6.95). There were significant differences in Angle, K , MA and LY30 values between the different neonatal day age groups. Conclusion This study preliminarily establishes a reference range for TEG parameters during the neonatal period. The age of a newborn had a large influence on TEG parameters. Additionally, we demonstrated a correlation between laboratory tests and TEG parameters for this age period. The reference values provided herein are meaningful for future studies.
机译:摘要介绍所获得的凝血疾病是新生儿出血的常见原因。血栓精膏(TEG)全面评估身体中的血压过程。遗憾的是,尚未评估新生儿期间TEG参数的参考范围,这限制了TEG在新生儿中的使用。在这项研究中,我们旨在建立新生儿期间TEG参数的参考范围。方法本研究包括371个全职婴儿(≥37?妊娠周),并根据年龄将这些婴儿分成三组,如下:1,2-7和8-28?天。我们使用TEG,凝血常规和血小板计数测试测量它们的外周血。我们分析了群体之间的差异。结果TEG参数的参考范围作为中位数和参考范围(2.5和97.5百分位数),如下:R(凝块反应时间,秒)4.80(2.80-7.17),角度(纤维蛋白生产率)69.90(44.91- 78.89),K(凝块动力学,min)1.40(0.80-4.50),MA(最大振幅,mm)63.50(44.34-74.66)和Ly30(30?分钟的裂解,%)0.10(0.10-6.95)。不同新生儿日龄群之间的角度,K,MA和LY30值有显着差异。结论本研究在新生儿期间预先建立了TEG参数的参考范围。新生儿的年龄对TEG参数有很大影响。此外,我们证明了该年龄期间的实验室测试和TEG参数之间的相关性。本文提供的参考值对于未来的研究有意义。

著录项

  • 来源
  • 作者单位

    Department of Blood Transfusion Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare;

    Department of Blood Transfusion Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare;

    Department of Blood Transfusion Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare;

    Department of Blood Transfusion Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare;

    Department of Blood Transfusion Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare;

    Department of Blood Transfusion Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 血液及淋巴系疾病;
  • 关键词

    neonatal period; neonate; reference range; thromboelastograph;

    机译:新生儿时期;新生儿;参考范围;血栓球运动仪;