Impact of maternal weight on the intra‐observer and inter‐observer reproducibility of fetal ultrasonography measurements in the third trimester

机译:母体重量对胎儿超声测量的观察者内部观察者和观察者间再现性的影响

获取原文
获取原文并翻译 | 示例

摘要

Abstract Objective To evaluate the effect of maternal weight on the intra‐ and inter‐observer reproducibility of third‐trimester ultrasonography fetal measurements. Methods The present prospective study, performed at a tertiary hospital, enrolled patients at between 35 +0 ?weeks and 36 +6 ?weeks of singleton pregnancies between January 1, 2015, and July 1, 2016. Fetal ultrasonography measurements were evaluated twice by a first observer and a third time by a second observer. Intra‐ and inter‐observer consistency were analyzed using the Cronbach α reliability coefficient, and measurement reproducibility was compared with patients stratified by a body mass index ( BMI , calculated as weight in kilograms divided by the square of height in meters) of below 25 or at least 25. Results The study included 197 patients (133 with BMI 25 and 64 with BMI ≥25). Among patients with a BMI below 25, the reliability coefficients for bi‐parietal diameter, head circumference, abdominal circumference, and femur length measurements were 0.97, 0.95, 0.98, and 0.96, respectively, for intra‐observer consistency, and were 0.97, 0.93, 0.98, and 0.95, respectively, for inter‐observer consistency. Among patients with a BMI of at least 25, these values were 0.97, 0.96, 0.98, and 0.97, respectively, for intra‐observed consistency, and 0.97, 0.94, 0.98, and 0.96, respectively, for inter‐observer consistency. Conclusion High intra‐ and inter‐observer reproducibility was observed for third‐trimester fetal ultrasonography measurements, including for patients who were overweight.
机译:摘要目的评价母体重量对三孕孕胎儿胎儿胎儿测量的观察者和观察者间再现性的影响。方法方法,在高等院医院进行,注册患者35 + 0的患者,2015年1月1日至2016年7月1日之间的单身怀孕。胎儿超声测量评估了两次第一个观察者和第三次通过第二个观察者。使用Cronbachα可靠性系数分析和观察者间的一致性,并将测量再现性与由体重指数(BMI)分层分层的患者进行比较,低于25或至少25.结果该研究包括197名患者(133名,BMI& 25和35例,BMI≥25)。 BMI患者在25以下,双间直径,头圆周,腹部圆周和股骨长度测量的可靠性系数分别为ObserAver内一致性分别为0.97,0.95,0.98和0.96,并且为0.97,0.93分别为观察者间的一致性0.98和0.95。在BMI的患者中,至少25的患者,这些值分别为0.97,0.96,0.98和0.97,分别用于观察到的稠度,0.97,0.94,0.98和0.96,用于观察者间稠度。结论对于第三三月胎儿超声测量测量,观察到高型和观察者间再现性,包括超重的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号