首页> 外文期刊>International Journal of Adhesion & Adhesives >Influencing factors, repeatability and correlation of chamber methods in measuring formaldehyde emissions from fiber- and particleboards
【24h】

Influencing factors, repeatability and correlation of chamber methods in measuring formaldehyde emissions from fiber- and particleboards

机译:测量纤维和刨花板测量甲醛排放的腔室方法的影响因素,可重复性和相关性

获取原文
获取原文并翻译 | 示例
           

摘要

Recently, there has been focus on lowering emission levels of wood-based boards. However, the accuracy and correlation between EN 717-1 and ASTM D 6007 chamber methods at emission levels below 0.05 ppm are not well investigated, and information about their con elation to the EN 16516 method is limited. In this paper, the low emission level of interest was determined by measuring emissions from particles, fibers and pressed boards without glue. The effect of analytical methods and edge-sealing on chamber emissions was determined, and accuracies and correlations of the EN 717-1 and ASTM D 6007 chambers were defined at low emission levels (< 0.05 ppm). In addition, some emission values were compared to those obtained with EN 16516. The EN 717-1 and ASTM D 6007 methods had high accuracy. The acetyl acetone and 2.4-dinitrophenylhydrazine analytical methods showed low standard deviations (< 5%), except at emission levels below 0.02 ppm. This could be counteracted by using a direct reagent absorber solution. Opening 5% of the edge of boards affected emissions and was dependent on board type. ASTM D 6007 and EN 717-1 methods were highly correlated for both particleboards (r(2) = 0.9167) and fiberboards (r(2) = 0.9443) at emission levels below 0.05 ppm. EN 16516 emissions were 2.6 times greater than those of EN 717-1 at emission range < 0.05 ppm, exceeding the conversion factor of two given in the German legislation. The EN 717-1 to EN 16516 correlation needs to be further evaluated for different board types and emission ranges.
机译:最近,一直专注于降低基于木板的辐射水平。然而,在低于0.05ppm的发射水平下的EN 717-1和ASTM D 6007腔室方法之间的准确性和相关性并不具体研究,并且关于它们对EN 16516方法的信息的信息受到限制。在本文中,通过测量没有胶水的颗粒,纤维和压板的排放来确定低排放景观。确定了分析方法和边缘密封对腔室排放的影响,并且在低发射水平(<0.05ppm)下定义了EN 717-1和ASTM D 6007室的精度和相关性。此外,将一些发射值与EN 16516获得的那些进行比较。EN 717-1和ASTM D 6007方法精度高。乙酰丙酮和2.4-二硝基苯基肼分析方法显示出低标准偏差(<5%),除外排放水平低于0.02ppm。可以通过使用直接试剂吸收溶液来抵消这一点。打开电路板边缘的5%受影响的排放,依赖于底板类型。 ASTM D 6007和EN 717-1的方法对于刨花板(R(2)= 0.9167)和纤维板(R(2)= 0.9443)在0.05ppm以下的发射水平下高度相关。在排放范围<0.05ppm时,EN 16516排放量大于EN 717-1的0.6倍,超过德国立法中给出的两种转换因子。 EN 717-1至EN 16516需要进一步评估不同的板类型和发射范围的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号