首页> 外文期刊>International Journal of Adhesion & Adhesives >Pull-off testing as an interfacial bond strength assessment of CFRP-concrete interface exposed to a marine environment
【24h】

Pull-off testing as an interfacial bond strength assessment of CFRP-concrete interface exposed to a marine environment

机译:作为暴露于海洋环境的CFRP混凝土界面的界面粘合强度评估

获取原文
获取原文并翻译 | 示例
           

摘要

The long-term performance of the bond between carbon fibre reinforced polymer composite (CFRP) fabrics and concrete substrate is crucial to estimations of the reliability of externally strengthened concrete structures. This paper presents the experimental results and analysis of 162 pull-off tests using nine concrete slabs under various environmental conditions, i.e., wet/dry cyclic exposure and full-immersion exposure of 3.5% salt-water at a temperature of 60 degrees C. The main objective of this study was to assess the effects on the bond performance of CFRP-strengthened concrete slabs during 12 months of exposure in a marine environment. Five types of failure modes were observed in the tested samples. The test results confirmed that 12 months of exposure in a marine environment had a low effect on the epoxy performance between CFRP and concrete. The results also indicated the marginal increase of pull-off strength values after 12 months of environmental exposure.
机译:碳纤维增强聚合物复合材料(CFRP)织物和混凝土基板之间的长期性能与外部强化混凝土结构的可靠性估计至关重要。 本文介绍了在各种环境条件下使用九个混凝土板的162个拉出试验的实验结果和分析,即在60℃的温度下湿/干循环暴露和3.5%盐水的全浸渍暴露。该 本研究的主要目的是评估在海洋环境暴露12个月内CFRP加强混凝土板的粘合性能的影响。 在测试的样品中观察到五种类型的失效模式。 测试结果证实,海洋环境中12个月的暴露对CFRP和混凝土之间的环氧性能有很大影响。 结果还表明,在环境暴露后12个月后的拉出强度值的边际增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号