...
首页> 外文期刊>International Journal of Applied Engineering Research >An Accuracy Analysis of Tumor Tracking Algorithm According to Types of Respiration
【24h】

An Accuracy Analysis of Tumor Tracking Algorithm According to Types of Respiration

机译:呼吸类型肿瘤跟踪算法的精度分析

获取原文
获取原文并翻译 | 示例

摘要

Purpose: In this study, derived type the optimal patient breathing through the precision analysis of tumor tracking algorithm in accordance with the respiratory type was applied to the Cyber-Knife SynchronyTM respiratory tumor tracking therapy. Methods: For the measurement, by End to End measurement method program of Cyber-Knife manufacturer using Dynamic Thorax and Gafchromic Film, Treatment Targeting Error (TTE) and Superior/Inferior Direction Error (SIDE) were analyzed at 90% and 95% dose thresholds, respectively. Results: 90% TTE in the Respiratory group I (regular) is 0.86±0.18 ~ 1.67±0.12, SIDE is -1.4±0.18 ~ -0.32±0.13, 95% error range of TTE is 1.05±0.19 ~ 2.34 ± 0.23, SIDE is -2.09±0.17 ~ 0.3±0.24. In the Respiration group II to stop (Hold) for aerobic respiration in 90% error range of TTE is 1.5±0.04 ~ 2.02±0.19, SIDE is -0.1±0.31 ~ 1.57±0.1. 95% error range of TTE is 1.31±0.13 ~ 2.33±0.13, SIDE is -0.05±0.34 ~ 1.67±0.2. In addition, in the Respiration group III (SI/RE) 90% error range of TTE is 1.29±0.39 ~ 2.32±0.24, SIDE is -1.31±0.18 ~ 1.2±0.21, 95% error range of TTE is 1.37±0.26 ~ 3.17±0.19, SIDE is -1.79±0.24 ~ 1.28±0.25. Conclusion: Patients should fully understand of the importance for a stable respiration and are well-informed of respiration prior to a 4-D CT scan and radiation therapy, and it is judged that it is very important to do tumor-tracking radiation therapy, After training them in respiration so that they come near to Respiration group through the advance respiratory training and have a stable respiration type.
机译:目的:在本研究中,通过根据呼吸型呼吸型肿瘤跟踪算法的精确分析来源型型型呼吸,用于网络 - 刀同步TM呼吸肿瘤跟踪治疗。方法:对于测量,通过使用动态胸部和Gafchromic薄膜的网络刀制造商结束到结束测量方法,治疗靶向误差(TTE)和上级/下方向误差(侧)以90%和95%剂量阈值分析, 分别。结果:90%TTE在呼吸组I(常规)是0.86±0.18〜1.67±0.12,侧为-1.4±0.18〜-0.32±0.13,TTE的95%误差范围为1.05±0.19〜2.34±0.23,侧是-2.09±0.17〜0.3±0.24。在呼吸组中,在90%误差范围内停止(保持)TTE的90%误差范围为1.5±0.04〜2.02±0.19,侧为-0.1±0.31〜1.57±0.1。 95%TTE的误差范围为1.31±0.13〜2.33±0.13,侧为-0.05±0.34〜1.67±0.2。此外,在呼吸组III(Si / RE)中,TTE的90%误差范围为1.29±0.39〜2.32±0.24,侧为-1.31±0.18〜1.2±0.21,TTE的95%误差范围为1.37±0.26〜 3.17±0.19,侧为-1.79±0.24〜1.28±0.25。结论:患者应充分了解稳定呼吸的重要性,并且在4-D CT扫描和放射治疗之前呼吸良好地通知,并且判断出肿瘤跟踪放射治疗非常重要,之后是非常重要的在呼吸中训练它们,使他们通过前进呼吸训练临近呼吸组,并具有稳定的呼吸型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号