...
首页> 外文期刊>International endodontic journal >Ultrasound examination for the detection of simulated periapical bone lesions in bovine mandibles: anex vivostudy
【24h】

Ultrasound examination for the detection of simulated periapical bone lesions in bovine mandibles: anex vivostudy

机译:超声检查检测牛下颌骨模拟的恐慌骨病变:Anex VivoStudy

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Aim To evaluate the accuracy of ultrasound examination (USE) for the detection of artificial bone defects in bovine mandibles in the absence of complete erosion of the cortical bone plate and to determine the minimum cortical thickness that constitutes a barrier for ultrasound waves. Methodology Sixty bovine mandibular anatomical blocks were harvested and uniformly distributed amongst six experimental groups. The negative control consisted of blocks with no intra-bony defects, whereas the positive control consisted of blocks with an artificial lesion of 2 mm diameter that perforated the buccal cortical bone plate. Two experimental groups comprised blocks with small (2 mm) and large (5 mm) artificial defects created under a cortical plate thinned to varying thicknesses. Two additional groups had small (2 mm) and large (5 mm) artificial defects that did not involve the cortical plate. After USE, the scans were saved and submitted to three blinded examiners. Sensitivity, specificity, predictive values and receiver-operating characteristics (ROC) were analysed. The significance of the findings (P < 0.05) was appraised using the chi-square statistics with the Yates correction, whilst the intra- and inter-examiner agreements were evaluated through Kappa statistics. Results USE was associated with high sensitivity (97.3%) and negative predictive value (89%), and a perfect score for specificity and positive predictive value. The ROC curve analysis revealed an accuracy of 97.8%. Thek-values were 0.86 and 0.89 for the first and second examinations, respectively, demonstrating very high inter-observer agreement. The intra-observer agreement was also high (k-value = 0.92). A significant correlation between the echographic diagnosis and the presence or absence of artificial intraosseous lesions in the anatomical blocks of bovine mandibles was observed (P < 0.0001). Conclusions USE was highly accurate and reliable for the detection of artificial lesions within bovine mandibles, regardless of the thickness or presence of the cortical plate.
机译:目的在没有皮质骨板的完全侵蚀的情况下,评估超声检查(使用)对牛颌骨中的人工骨缺陷的准确性,并确定构成超声波屏障的最小皮质厚度。方法,收获六十牛下颌骨质嵌段,均匀分布在六个实验组中。阴性对照包括没有骨内缺损的块,而阳性对照组由具有2mm直径为2mm的人工病变的块组成,其穿孔颊皮质骨板。两种实验组包含小(2mm)和大(5mm)的嵌段,在皮质板下稀薄到变化的厚度。另外两组较小(2毫米)和大(5毫米)的人工缺陷,不涉及皮质板。使用后,扫描被保存并提交给三位盲目的审查员。分析了灵敏度,特异性,预测值和接收器操作特征(ROC)。研究结果(P <0.05)的意义使用Chi-Square统计数据与Yate Relection进行了评估,同时通过Kappa统计评估了审查内的和审查间协议。结果使用与高灵敏度(97.3%)和负预测值(89%)相关,以及特异性和阳性预测值的完美分数。 ROC曲线分析显示了97.8%的准确性。对于第一和第二次检查分别展示了非常高的观察员协议,THE值为0.86和0.89。观察员内的协议也很高(K值= 0.92)。观察到回声诊断与人工骨质病变的显着相关性,在牛颌骨的解剖块中(P <0.0001)。结论使用对牛颌骨内的人工病变进行高度准确和可靠,无论皮质板的厚度或存在如何。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号