Aim To investigate simultaneously the effect of voxel size and fracture width on the accuracy of detecting vertical root fractures (VRFs) in non-root filled teeth when using cone beam computed tomography. Methodology Fifty-one of 161 extracted human permanent teeth (16 anterior teeth, 132 premolars and 13 mandibular molars) were selected randomly for VRF induction with two fracture widths. All teeth were scanned with four CBCT units at different voxel sizes provided by the units. Three observers classified the presence or absence of VRF using a 5-point scale. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the ROC curve (AUC) were calculated. AUCs amongst voxel sizes and between the fracture widths were compared using the Z test. Intra- and inter-observer agreement was assessed using weighted Cohen kappa. Results For the NewTom VGi and ProMax 3D Mid CBCT unit, no significant differences were found amongst voxel sizes for the AUCs, irrespective of the fracture width (P > 0.05). There were significant differences between images scanned with voxel size 250 and 160 mu m (P = 0.02), and images scanned with voxel size 250 and 80 mu m for AUCs in the narrow VRF group for the 3D Accuitomo 170 unit (P = 0.03). For i-CAT FLX, significant differences were found between the voxel protocols of 300 mu m and of the other three voxel sizes for AUC, sensitivity and NPV (P < 0.05). Significant differences between the wide and the narrow VRF groups for AUCs were found for 3D Accuitomo 170 (P = 0.01) and ProMax 3D Mid (P < 0.01). Conclusions Cone beam computed tomography was accurate for detecting VRF in non-root filled teeth. Fracture width had an effect on the detection of VRF. The effect of the voxel size on the detection of VRF depended on the CBCT unit used.
机译:目的是同时探讨体素尺寸和断裂宽度对使用锥形光束计算机断层扫描时检测非根填充齿中的垂直根部裂缝(VRF)的准确性的效果。方法中511个提取的人常可齿(16前齿,132颗前牙齿和13个下颌摩尔)被随机选择,用于两种骨折宽度的VRF诱导。所有牙齿均用由单位提供的不同体素尺寸的四个CBCT单元扫描。三个观察者使用5分尺度分类VRF的存在或不存在。计算ROC曲线(AUC)下的敏感性,特异性,阳性预测值(PPV),负预测值(NPV)和面积。使用Z检验比较体素尺寸和裂缝宽度之间的AUC。使用加权Cohen Kappa评估了和观察者间协议。结果为纽特罗姆VGI和Promax 3D中CBCT单元,无论骨折宽度(P> 0.05)都没有发现Voxel尺寸的显着差异。扫描Voxel尺寸250和160μm(p = 0.02)扫描的图像之间存在显着差异,并且在3D驻留的VRF组中扫描Voxel大小250和80μm的图像,用于3D驻留件170单元(P = 0.03) 。对于I-CAT FLX,血素协议在300μm和其他三种体素尺寸的血管素,敏感性和NPV之间发现了显着差异(P <0.05)。发现AUCS的宽和窄VRF组之间的显着差异为3D轴颈170(P = 0.01)和Promax 3D中期(P <0.01)。结论锥形光束计算机断层扫描准确用于检测非根填充牙齿的VRF。裂缝宽度对VRF的检测产生了影响。体素大小对VRF检测的影响依赖于所用CBCT单元。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号