首页> 外文期刊>International endodontic journal >Using Meglumine Diatrizoate to improve the accuracy of diagnosis of cracked teeth on Cone‐beam CT images
【24h】

Using Meglumine Diatrizoate to improve the accuracy of diagnosis of cracked teeth on Cone‐beam CT images

机译:使用Meglumine诽谤液提高锥形梁CT图像曲折牙齿诊断的准确性

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract Aim To explore in a laboratory setting the feasibility of using Meglumine Diatrizoate (MD) to improve the accuracy of diagnosis of cracked teeth on cone‐beam CT (CBCT) images. Methodology Twenty‐four teeth were cracked artificially by soaking them cyclically in liquid nitrogen and hot water. The number and position of crack lines were evaluated with a dental operating microscope and used as the gold standard. The artificially cracked teeth were then examined using routine scanning (RS) and enhanced scanning (ES) modes, respectively. For the ES mode, MD was painted on the surface of the crack lines, and then, CBCT scanning with the same parameters was performed after 10?min. A radiological graduate student and an experienced radiologist evaluated the presence or absence of crack lines, respectively. The differences between the RS and ES modes were determined and assessed using McNemar’s test. Inter‐examiner agreement and intra‐examiner agreement were assessed using kappa analysis. Results Fifty‐seven crack lines were found in the 24 cracked teeth. In the RS mode, the accuracy of detection of crack lines was 23% (radiological graduate student) and 32% (experienced radiologist), whereas in the ES mode, the accuracy was 61% (radiological graduate student) and 65% (experienced radiologist). The inter‐examiner agreement was 0.693 in RS mode and 0.849 in ES mode. The intra‐examiner agreement was 0.872 and 0.949 for the radiological graduate student in RS and ES mode respectively; and one for the experienced radiologist both in RS and ES mode. Conclusions Compared with routine scanning mode, more crack lines could be detected in enhanced scanning mode using Meglumine Diatrizoate as a contrast medium. MD could be a potential contrast medium to improve the accuracy of detection of crack lines on CBCT images.
机译:摘要旨在在实验室探索使用Meglumine DiaTrizoate(MD)的可行性来提高锥形束CT(CBCT)图像上的裂纹齿的诊断准确性。通过在液氮和热水中循环浸泡,将24颗牙齿浸泡在液氮和热水中的方法中裂解方法。用牙科手术显微镜评估裂缝线的数量和位置,用作金标准。然后使用常规扫描(RS)和增强扫描(ES)模式检查人工破裂的牙齿。对于ES模式,MD被涂在裂缝线的表面上,然后在10℃下进行具有相同参数的CBCT扫描。放射性研究生和经验丰富的放射科医生分别评估了裂缝线的存在或不存在。使用McNemar的测试确定并评估RS和ES模式之间的差异。使用Kappa分析评估审查间协议和审查内部协议。结果在24颗破裂的牙齿中发现了五十七条裂缝线。在RS模式下,裂缝线的检测准确性为23%(放射学研究生)和32%(经验丰富的放射科医师),而在ES模式下,准确性为61%(放射学生)和65%(经验丰富的放射科医师)。审查间协议中的互相协议为0.693以RS模式和0.849以ES模式为0.849。 RS和ES模式的放射性研究生分别为0.872和0.949年为0.872和0.949;并且一个用于RS和ES模式的经验丰富的放射科医生。结论与常规扫描模式相比,可以使用Meglumine DiaTrizoate作为造影剂的增强扫描模式来检测更多的裂缝线。 MD可以是潜在的造影介质,以提高CBCT图像上的裂缝线的检测准确性。

著录项

  • 来源
    《International endodontic journal》 |2020年第5期|共6页
  • 作者单位

    Department of Dentomaxillofacial RadiologyNanjing Stomatological HospitalNanjing China;

    Department of Dentomaxillofacial RadiologyNanjing Stomatological HospitalNanjing China;

    Department of Dentomaxillofacial RadiologyNanjing Stomatological HospitalNanjing China;

    Department of Dentomaxillofacial RadiologyNanjing Stomatological HospitalNanjing China;

    Department of Dentomaxillofacial RadiologyNanjing Stomatological HospitalNanjing China;

    Department of Dentomaxillofacial RadiologyNanjing Stomatological HospitalNanjing China;

    Department of StomatologyThird People’s Hospital of Danyang CityDanyang China;

    Department of EndodonticsNanjing Stomatological HospitalNanjing China;

    Department of Dentomaxillofacial RadiologyNanjing Stomatological HospitalNanjing China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 口腔科学;
  • 关键词

    cone‐beam CT; cracked tooth; diagnosis; meglumine diatrizoate;

    机译:锥梁CT;裂纹牙齿;诊断;MELULUMINE诽谤;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号