Ability to detect endodontic complications using three different cone beam computed tomography units with and without artefact reduction modes: an ex?vivo ex?vivo study

机译:使用三种不同的锥形光束计算机断层扫描单元检测牙髓性并发症的能力,其中没有人工制品:EX?体内EX?VIVO研究

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Aim To assess observer performance in detecting?endodontic complications using three different cone beam computed tomography ( CBCT ) units with and without the application of artefact reduction modes. Methodology The study involved 40 freshly extracted human mandibular teeth ( n? = ? 10 per group) and divided randomly into four endodontic complication groups. Group 1) Instrument fracture; Group 2) Strip perforation; Group 3) Canal underfilling; and Group 4) Canal overfilling. Images of each tooth were obtained using three different CBCT units offering artefact reduction algorithms: the ProMax 3D Max, the Pax Flex 3D and the Dentri S. Four observers evaluated the images for the presence/absence of the four simulated endodontic complications. Weighted kappa coefficients and intra‐class correlation coefficients ( ICC s) were calculated to reveal the intra‐ and inter‐observer agreement for each imaging mode, respectively. Receiver operating characteristic ( ROC ) analysis was used to evaluate the observers’ performance. DeLong tests were used to compare the results for each image mode and observer using a significance level of α?=?0.05. Results In each of the four simulated endodontic complication groups, no significant differences were observed with and without application of artefact reduction for any of the three CBCT units tested. Only two significant differences were detected, and both were between the ProMax 3D Max at low mode AR and ProMax 3D Max without AR : observer 2 in group 1 ( P? = ? 0.0001) and observer 4 in group 4 ( P? = ? 0.0256). Conclusion For each of the three CBCT units tested, application of artefact reduction for detecting endodontic complications is not recommended as a routine tool.
机译:摘要旨在评估检测观察者的性能吗?使用三种不同锥形光束计算机断层扫描(CBCT)单位的牙髓性能,在不应用人工制品中的应用。方法研究涉及40新提取的人颌骨牙齿(N?= 10.每组10),并随机分成四个牙髓并发症组。第1组)仪器骨折;第2组)剥离穿孔;第3组)运河欠下;和第4组)运河过期。使用三种不同的CBCT单元提供的每种牙齿的图像提供了三种不同的CBCT单元:Promax 3D Max,Pax Flex 3D和Dentri S.4观察者评估了四种模拟牙髓并发症的存在/不存在的图像。计算加权Kappa系数和类内相关系数(ICC S)分别为每个成像模式揭示了对观察者互相的协议。接收器操作特征(ROC)分析用于评估观察者的性能。 DELONG测试用于将每个图像模式和观察者的结果进行比较,使用α的显着性水平?= 0.05。结果在四种模拟的牙髓并发症组中的每一个中,未观察到任何三种CBCT单元中的任何三种CBCT单元的人工制品减少的显着差异。只检测到两个显着差异,两者都在低模式AR的Promax 3D Max之间,并且在第1组(P?= 0.0001)和第4组中的观察者2中的观察者2(P?=?0.0256 )。结论对测试的三个CBCT单元中的每一个,不建议在常规工具中施加检测牙髓并发症的伪造。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号