Analysis of the fit of modern pre-contoured distal femur plates: Expect an imperfect contour

机译:现代前期股骨板配合分析:期待不完美的轮廓

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The purpose of this study was to determine if the contour of current distal femur plates can reliably be used as a reduction tool and to determine if the presence of a total knee arthroplasty (TKA) influences fit. Thirty-two patients were retrospectively reviewed. Radiographs of 19 patients with normal knees and 21 patients who had undergone TKA were evaluated. Using TraumaCad templating software, the contours of 4 different modern distal femur plates (Depuy Synthes, Stryker, Zimmer Biomet, and Smith & Nephew) were analyzed using a novel measurement technique to evaluate plate fit. To mimic non-locking screws in the shaft, the template was placed on the shaft and the plate to bone (PTB) and condyle to plate (CTP) distances were recorded. The PTB distance measured how closely the plate matched the contour of the metaphyseal flare, while the CTP value represented the distance from the plate to the distal articular surface. Larger PTB and CTP distances represent a higher mismatch between the patient's anatomy and the contour of the plate. There was significant variability in plate fit in all patients. None of the plates fit the patient's anatomy well, with PTB values averaging from 5.5 mm to 9.2 mm. There was no significant difference between normal radiographs and TKA radiographs, suggesting that the presence of a TKA may not contribute to plate fit. The results of this study show that current plate designs may not match the patient's native anatomy prior to fracture. Therefore, caution should be utilized when using non-locking screws in the shaft and using the pre-contoured nature of the plate as a template for reduction. The authors advocate for careful preoperative planning and using contralateral radiographs for templating purposes to prevent malreduction and to assist in device selection for the best device fit per patient. (C) 2020 Elsevier Ltd. All rights reserved.
机译:本研究的目的是确定电流远端股骨板的轮廓可以可靠地用作还原工具,并确定是否存在全膝关节成形术(TKA)的影响。回顾性审查了三十二名患者。评估了19例正常膝盖和21例患者的Xdartopls评估了TKA。使用创伤模板软件,使用新的测量技术分析4种不同现代股骨板(Depuy Synthes,Stryker,Zimmer Biomet和史密斯和史密斯和史密斯和史密斯和史密斯&侄子)。为了模仿轴中的非锁定螺钉,将模板放置在轴上,并将板上置于骨骼(PTB)并记录到板(CTP)距离。 PTB距离测量了板材匹配的形过激性闪光的轮廓的距离,而CTP值表示从板到远端关节表面的距离。较大的PTB和CTP距离表示患者的解剖结构和板的轮廓之间的更高不匹配。所有患者的板材都有显着的变化。没有一块板均符合患者的解剖结构,PTB值平均为5.5mm至9.2mm。正常射线照相和TKA射线照片之间没有显着差异,表明TKA的存在可能不会有助于平板合适。该研究的结果表明,在骨折之前,电流板设计可能与患者的天然解剖学不符。因此,应在轴中使用非锁定螺钉并使用板的预剥离性质作为减少模板时,应使用小心。作者倡导仔细的术前规划,并使用对侧射线照片进行模板目的,以防止缩略一体,并协助每个患者的最佳设备的设备选择。 (c)2020 elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号