...
首页> 外文期刊>Acta Radiologica >Breast cancers initially detected by hand-held ultrasound: detection performance of radiologists using automated breast ultrasound data.
【24h】

Breast cancers initially detected by hand-held ultrasound: detection performance of radiologists using automated breast ultrasound data.

机译:最初通过手持式超声检测的乳腺癌:放射科医生使用自动乳房超声数据的检测性能。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Ultrasonography (US) has been used as an important adjunct to mammography (MG), and automated breast US (ABUS) scanners were originally designed to effectively examine the breast in its entirety. PURPOSE: To retrospectively assess the performance of radiologists in the detection of breast cancers, initially detected by hand-held ultrasound (HHUS), using 3D breast volume data obtained from a commercial ABUS system. MATERIAL AND METHODS: Bilateral whole breast US was performed using ABUS in 61 consecutive women who were scheduled to undergo US-guided needle biopsy due to suspicious breast masses detected during screening HHUS. Fourteen cancers in 13 women and 48 normal breasts of 48 women with benign disease in the contralateral breast were selected. Three radiologists who had not performed the HHUS examinations independently reviewed the 3D ABUS data for any lesions that required recall for further evaluation. Sensitivities and false-positive rates were calculated. RESULTS: The sensitivities of the three readers for cancer detection were 78.6% (11/14), 78.6%, and 57.1% (8/14), respectively, with false-positive rates of 20.8% (10/48), 12.5% (6/48) and 8.3% (4/48). Seven cancers were detected by all three readers, four cancers by two readers, and one cancer by one reader. Two invasive cancers were not detected by any reader. CONCLUSION: Of HHUS-detected cancers, only 57.1-78.6% were identified with ABUS. A substantial level of experience and training is necessary to improve cancer detection by ABUS.
机译:背景技术:超声检查(US)已被用作乳房X线照相术(MG)的重要辅助手段,而自动乳房US(ABUS)扫描仪最初被设计用来有效地检查整个乳房。目的:使用从商业ABUS系统获得的3D乳房体积数据,回顾性评估放射科医生在检测乳腺癌中的性能,最初是通过手持超声(HHUS)检测到的。材料和方法:由于在筛查HHUS期间发现可疑的乳房肿块,计划接受61例行US引导穿刺活检的连续61例女性,均使用ABUS进行双侧全乳US。选择对侧乳房中有良性疾病的48名女性中的13名女性和48名正常乳房中的14种癌症。三名没有进行HHUS检查的放射科医生独立检查了3D ABUS数据,以了解需要召回以进行进一步评估的任何病变。计算敏感性和假阳性率。结果:这三名读者对癌症检测的敏感性分别为78.6%(11/14),78.6%和57.1%(8/14),假阳性率分别为20.8%(10/48),12.5% (6/48)和8.3%(4/48)。所有三个阅读器检测到七个癌症,两个阅读器检测到四个癌症,一个阅读器检测到一个癌症。任何读者都未检测到两种浸润性癌症。结论:在HHUS检测到的癌症中,只有57.1-78.6%的ABUS被发现。必须有大量的经验和培训,才能改善ABUS对癌症的检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号