首页> 外文期刊>Acta Radiologica >Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases.
【24h】

Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases.

机译:de增强的三维磁化准备的快速梯度回波(3D MP-RAGE)成像在描述脑转移方面优于自旋回波成像。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: Precisely defining the number and location of brain metastases is very important for establishing a treatment strategy for malignancies. Although magnetic resonance imaging (MRI) is now considered the best modality, various improvements in sequences are still being made. PURPOSE: To prospectively compare the diagnostic ability of three-dimensional, magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging in detecting metastatic brain tumors, with that of two-dimensional spin-echo (2D SE) T1-weighted imaging. MATERIAL AND METHODS: A total of 123 examinations were included in this study, and 119 examinations from 88 patients with known malignancies were analyzed. All patients underwent T1- and T2-weighted 2D SE transverse imaging, followed by gadolinium-enhanced T1-weighted transverse and coronal 2D SE imaging and 3D MP-RAGE transverse imaging. Four radiologists interpreted the images to compare the accuracy and the time required for interpretation for each imaging. RESULTS: 3D MP-RAGE imaging was significantly better than 2D SE imaging for detecting metastatic brain lesions, regardless of the readers' experience. The sensitivities of the 3D MP-RAGE and 2D SE imaging for all observers were 0.81 vs. 0.80 (P>0.05), specificities were 0.93 vs. 0.87 (P<0.05), positive predictive values were 0.92 vs. 0.86 (P<0.05), negative predictive values were 0.78 vs. 0.75 (P>0.05), and accuracies were 0.84 vs. 0.78 (P<0.05), respectively. There was no significant difference in the time required for image interpretation between the two modalities (15.6+/-4.0 vs. 15.4+/-4.1 min). CONCLUSION: 3D MP-RAGE imaging proved superior to 2D SE imaging in the detection of brain metastases.
机译:背景:准确确定脑转移瘤的数量和位置对于建立恶性肿瘤治疗策略非常重要。尽管现在磁共振成像(MRI)被认为是最好的方式,但是序列的各种改进仍在进行中。目的:前瞻性比较三维磁化快速梯度回波(3D MP-RAGE)成像在检测转移性脑肿瘤中的诊断能力,以及二维自旋回波(2D SE)T1加权成像的诊断能力。材料与方法:本研究共包括123项检查,并对88例已知恶性肿瘤患者的119项检查进行了分析。所有患者均进行了T1和T2加权2D SE横向成像,然后进行了g增强的T1加权横向和冠状2D SE成像以及3D MP-RAGE横向成像。四位放射科医生对图像进行解释,以比较每次成像的解释准确性和时间。结果:无论读者的经验如何,3D MP-RAGE成像在检测转移性脑病变方面均明显优于2D SE成像。所有观察者的3D MP-RAGE和2D SE成像灵敏度分别为0.81对0.80(P> 0.05),特异性为0.93对0.87(P <0.05),阳性预测值为0.92对0.86(P <0.05) ),阴性预测值分别为0.78和0.75(P> 0.05),准确度分别为0.84和0.78(P <0.05)。两种模态之间的图像解释所需时间没有显着差异(15.6 +/- 4.0与15.4 +/- 4.1分钟)。结论:3D MP-RAGE成像在脑转移检测中被证明优于2D SE成像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号