...
首页> 外文期刊>Autoimmune diseases >Evaluation of a multiplex ELISA for autoantibody profiling in patients with autoimmune connective tissue diseases.
【24h】

Evaluation of a multiplex ELISA for autoantibody profiling in patients with autoimmune connective tissue diseases.

机译:自身免疫性结缔组织疾病患者自身抗体分析的复合ELISA评价。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The performance of immunoassays for the detection of autoantibodies is of critical importance in the diagnosis and assessment of patients with autoimmune connective tissue diseases (ACTD). Our objective was to compare the features of two multiplexed assays-INNO-LIA ANA and Gennova-PictArray ENA ELISA-for measurement of multiple autoantibodies and their utility as a clinical tool in ACTD diagnosis. The antigens included SS-A/Ro (60 and 52), SSB/La, Sm, Sm/RNP, CENP-B, Jo-1, and Scl-70. Stored sera from 85 ACTD patients and 80 controls consisting of patients with vasculitis, rheumatoid arthritis and infectious diseases, as well as healthy subjects were analyzed jointly with clinical and laboratory data. Agreement between the two methods varied between 58 and 99% (Cohen's kappa: 0.21-0.71) mostly for SSA and SSB. The frequency of specific autoantibodies measured using the two methods was more variable for SSA, SSB, and RNP/Sm. There were a higher number of ambiguous results when using INNO-LIA. The optimized cut-off values of the Gennova-PictArray resulted in over 99% specificities in samples obtained from the control group. Sensitivity patterns were more accurate in Gennova-PictArray than in INNO-LIA, as suggested in previously reported studies. A third method could be applied to determine which of the two methods is more accurate.
机译:免疫测定对于检测自身抗体的性能对于自身免疫结缔组织疾病(ACTD)患者的诊断和评估至关重要。我们的目标是比较两种多路复用的分析 - Inno-Lia Ana和Gennova-Pictarray ena ELISA的功能 - 用于测量多种自身抗体及其效用作为诊断的临床工具。抗原包括SS-A / RO(60和52),SSB / LA,SM,SM / RNP,CENP-B,JO-1和SCL-70。储存血清来自85例患者和80例对照组成,包括患有血管炎,类风湿性关节炎和传染病,以及健康受试者,并与临床和实验室数据分析。两种方法之间的协议在58到99%之间(Cohen的Kappa:0.21-0.71)多,主要用于SSA和SSB。使用这两种方法测量的特定自身抗体的频率对于SSA,SSB和RNP / SM更具变量。使用Inno-Lia时,有一个更高数量的含糊不清的结果。 Gennova-Pictarray的优化截止值导致从对照组获得的样品中超过99%的特异性。在先前报道的研究中提出的建议,敏感模式比诺奥利亚更准确。可以应用第三种方法来确定两种方法中的哪一种更准确。

著录项

  • 来源
    《Autoimmune diseases》 |2014年第1期|共1页
  • 作者

    Caro Pérez A;

  • 作者单位

    Gennova Research Gennova Scientific S.L. Seville Spain.;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 内科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号