An electrospray chemical ionization source for real-time measurement of atmospheric organic and inorganic vapors

机译:用于实时测量大气有机和无机蒸汽的电喷雾化学电离源

获取原文
获取原文并翻译 | 示例

摘要

We present an electrospray ion source coupled to an orthogonal continuous-flow atmospheric pressure chemical ionization region. The source can generate intense and stable currents of several specific reagent ions using a range of salt solutions prepared in methanol, thereby providing both an alternative to more common radioactive ion sources and allowing for the generation of reagent ions that are not available in current chemical ionization mass spectrometry (CIMS) techniques, such as alkaline cations. We couple the orthogonal electrospray chemical ionization (ESCI) source to a high-resolution time-of-flight mass spectrometer (HR-ToF-MS), and assess instrument performance through calibrations using nitric acid (HNO3), formic acid (HCOOH), and isoprene epoxydiol (trans-beta-IEPOX) gas standards, and through measurements of oxidized organic compounds formed from ozonolysis of alpha-pinene in a continuous-flow reaction chamber. When using iodide as the reagent ion, the HR-ToF-ESCIMS prototype has a sensitivity of 11, 2.4, and 10 cps pptv(-1) per million counts per second (cps) of reagent ions and a detection limit (3 sigma, 5 s averaging) of 4.9, 12.5, and 1.4 pptv to HNO3, HCOOH, and IEPOX, respectively. These values are comparable to those obtained using an iodide-adduct HR-ToF-CIMS with a radioactive ion source and low-pressure ion-molecule reaction region. Applications to the alpha-pinene ozonolysis system demonstrates that HRT-oF-ESCIMS can generate multiple reagent ions (e.g., I-, NO3-, acetate, Li+, Na+, K+, and NH4+ having different selectivity to provide a comprehensive molecular description of a complex organic system.
机译:我们介绍了一个耦合到正交连续流动大气压化学电离区域的电喷雾离子源。使用在甲醇中制备的一系列盐溶液可以产生几种特定试剂离子的强烈稳定的电流,从而提供更常见的放射性离子源并允许产生当前化学电离中不可用的试剂离子的产生质谱(CIMS)技术,例如碱性阳离子。我们将正交电泵化学电离(ESCI)源连接到高分辨率飞行时间质谱仪(HR-TOF-MS),并通过使用硝酸(HNO3),甲酸(HCOOH)来评估仪器性能,和异戊二烯环氧二醇(Trans-Beta-IePox)气体标准,并通过测量由在连续流动反应室中的α-突烯的臭氧分解形成的氧化有机化合物。当使用碘化物作为试剂离子时,HR-TOF-ESCIMS原型的灵敏度为11,2.4和10cps pptv(-1)每秒每秒(cps)的试剂离子和检测极限(3 sigma, 5秒的平均分别为4.9,12.5和1.4 pptv,分别给HNO3,HCOOH和IEPOX。这些值与使用具有放射性离子源和低压离子分子反应区域的碘化物加合金HR-TOF-CIM获得的值相当。 α-脊烯臭氧分解系统的应用表明,ESCIMS的HRT-ESCIMS可以产生多种试剂离子(例如,,NO 3 - ,乙酸盐,Li +,Na +,K +和NH 4 +,其具有不同的选择性,以提供综合分子描述复杂的有机系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号