首页> 外文期刊>Acta Radiologica >Pediatric multidetector computed tomography using tube current modulation and a patient image gallery.
【24h】

Pediatric multidetector computed tomography using tube current modulation and a patient image gallery.

机译:儿科多探测器计算机断层扫描,使用管电流调制和患者图像库。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Dose reduction is crucial in pediatric multidetector computed tomography (MDCT). PURPOSE: To perform pediatric 16-slice MDCT using tube current modulations and to adjust prospectively the tube current using a patient image gallery (IG) providing simulated dose-reduced protocols; and to evaluate and compare the image quality of the IG and the clinical MDCT. MATERIAL AND METHODS: 30 examinations (thorax, n = 15; abdomen, n = 8; pelvis, n = 7) in 20 patients (nine male, age 8.05 +/- 7.33 years, weight 29.8 +/- 24.02 kg) were performed according to an IG on a 16-slice MDCT with additional use of online tube current modulation (CARE Dose). Three radiologists visually assessed image quality from the IG and actual 16-slice MDCT scans. For objective analysis, image noise was determined. RESULTS: Statistical analysis showed moderate concordance in objective (K = 0.68-0.78) and subjective (K = 0.33-0.64) image assessment between the IG and clinical 16-slice MDCT scans. Depending on the weight group and clinical question, no or only minor dose reductions in the chest, but moderate to considerable reductions in the abdominal/pelvic 16-slice MDCT scans compared to previously used pediatric protocols were achieved. Extra dose reduction was achieved due to additional use of CARE Dose depending on age group and scan region (mean 8.6-23.9%). CONCLUSION: The IG enabled us to prospectively reduce the tube current and adapt the required image quality to the clinical question. Additional dose reduction was achieved with application of CARE Dose; nevertheless, the images are comparable to the simulated images of the IG.
机译:背景:剂量减少在小儿多探测器计算机断层扫描(MDCT)中至关重要。目的:使用电子管电流调制技术进行儿科16层MDCT,并使用提供模拟剂量减少方案的患者影像库(IG)预先调整电子管电流;并评估和比较IG和临床MDCT的图像质量。材料与方法:对20例患者(男性9例,年龄8.05 +/- 7.33岁,体重29.8 +/- 24.02 kg)进行了30次检查(胸部,n = 15;腹部,n = 8;骨盆,n = 7)。根据IG在16层MDCT上的介绍,另外使用了在线电子管电流调制(CARE Dose)。三名放射科医生从IG和实际的16层MDCT扫描中视觉评估了图像质量。为了进行客观分析,确定了图像噪声。结果:统计分析显示,在IG和16层MDCT扫描之间,客观(K = 0.68-0.78)和主观(K = 0.33-0.64)图像评估具有中等一致性。根据体重组和临床问题,与以前使用的儿科治疗方案相比,没有或只有很小的胸部剂量减少,但腹部/骨盆16层MDCT扫描有中等或相当大的减少。由于根据年龄组和扫描区域的不同使用了CARE剂量,因此可实现额外的剂量减少(平均8.6-23.9%)。结论:IG使我们能够前瞻性地降低管电流,并使所需的图像质量适应临床问题。通过使用CARE剂量可进一步降低剂量;但是,这些图像可与IG的模拟图像相比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号