Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study

机译:使用压制巨型杯子的髋臼修饰关节成形术:平均10年的后续研究

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction Acetabular revision arthroplasty using jumbo cups for moderate-to-severe acetabular defects has varied outcomes. We evaluated the clinical and radiological outcomes of acetabular revision arthroplasty using a press-fitted jumbo cup and sought to identify factors that influence outcomes during intermediate follow-up. Materials and methods Eighty patients (47 men, 33 women; 80 hips) who underwent acetabular revision arthroplasty using press-fitted jumbo cups were included. The mean follow-up period was 10.4 years. Harris hip score (HHS), presence of groin pain, radiographic results, and Kaplan-Meier survival curves were evaluated. Implant design and surgery-related and patient-related factors were assessed to identify influential factors for cup loosening. Migration and wear analyses were performed using Einzel-Bild-Rontgen-Analyse software. Results The mean preoperative HHS of 53 had improved to 77 at the final follow-up (p = 0.005). Nine patients experienced groin pain. Acetabular cup loosening was observed in seven cups (8.7%), and one jumbo cup was replaced with a reinforcement cage. The survival rate of the acetabular cup was 91% at 16 years according to the Kaplan-Meier analysis. Osteolysis was identified around the cup in six cases (7.5%). Acetabular cup loosening occurred more frequently in patients with conventional polyethylene liners than in those with highly cross-linked polyethylene liners (p = 0.045). The mean total migration was 1.52 mm, and the mean total wear was 0.98 mm. There was a positive correlation between total migration and total wear (p = 0.023; Spearman's rho = 0.388). The mean wear rate of the patients with the cup inclination angle < 50° was significantly lower than those with the cup inclination angle >50° (p = 0.001). There were four cases of complications (three dislocations and one infection) that did not require revision surgery. Conclusion Press-fitted jumbo cups for acetabular revision arthroplasty exhibited encouraging results during follow-up for an average of 10 years. Use of highly cross-linked polyethylene liners and proper placement of the acetabular component with an inclination angle < 50° may contribute to better clinical outcomes after acetabular revision arthroplasty with jumbo cups.
机译:引言髋臼修饰关节成形术,用于中度至严重的髋臼缺陷的巨型杯子具有多种结果。我们使用压制巨型杯杯评估了髋臼修订关节成形术的临床和放射性结果,并试图识别在中间后续期间影响结果的因素。包括材料和方法8岁患者(47名男性,33名女性; 80髋),使用压配巨型杯子接受髋臼修饰关节成形术。平均随访期为10.4岁。评估了哈里斯臀部评分(HHS),腹股沟疼痛,放射线摄影结果和Kaplan-Meier存活曲线的存在。评估植入性设计和外科与手术相关的因素,以确定杯子松动的影响因素。使用Einzel-Bild-Rontgen-Analyze软件进行迁移和磨损分析。结果53的平均术前HHS在最终随访中改善了77(p = 0.005)。九名患者经历了腹股沟疼痛。在7杯(8.7%)中观察到髋臼杯松动,并用钢筋笼替换一个巨大杯。根据Kaplan-Meier分析,16年髋臼杯的存活率为91%。在6例(7.5%)周围杯周围鉴定了骨液。常规聚乙烯衬垫患者比在高度交联的聚乙烯衬里(P = 0.045)中更频繁地发生髋臼杯松动。平均总迁移为1.52毫米,平均总磨损为0.98毫米。总迁移与总磨损之间存在正相关(P = 0.023; Spearman的Rho = 0.388)。杯倾斜角度<50°患者的平均磨损率明显低于杯倾角> 50°(P = 0.001)。有4例并发症(三个脱位和一种感染),不需要修正手术。结论髋臼修订关节成形术的压力巨型杯子在随访期间表现出令人鼓舞的结果平均10年。使用高度交联的聚乙烯衬垫和倾斜角度的适当放置纵向角度<50°可能会导致髋臼杯的髋臼修订关节置换术后更好的临床结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号