首页> 外文期刊>Archives of disease in childhood >Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing.
【24h】

Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing.

机译:随机对照试验在社会住房中幼儿浴热自来水温度降低浴热自来水温度。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVES: To assess the effectiveness of thermostatic mixing valves (TMVs) in reducing bath hot tap water temperature, assess acceptability of TMVs to families and impact on bath time safety practices. DESIGN: Pragmatic parallel arm randomised controlled trial. SETTING: A social housing organisation in Glasgow, Scotland, UK. PARTICIPANTS: 124 families with at least one child under 5 years. INTERVENTION: A TMV fitted by a qualified plumber and educational leaflets before and at the time of TMV fitting. MAIN OUTCOME MEASURES: Bath hot tap water temperature at 3-month and 12-month post-intervention or randomisation, acceptability, problems with TMVs and bath time safety practices. RESULTS: Intervention arm families had a significantly lower bath hot water temperature at 3-month and 12-month follow-up than families in the control arm (3 months: intervention arm median 45.0 degrees C, control arm median 56.0 degrees C, difference between medians, -11.0, 95% CI -14.3 to -7.7); 12 months: intervention arm median 46.0 degrees C, control arm median 55.0 degrees C, difference between medians -9.0, 95% CI -11.8 to -6.2) They were significantly more likely to be happy or very happy with their bath hot water temperature (RR 1.43, 95% CI 1.05 to 1.93), significantly less likely to report the temperature as being too hot (RR 0.33, 95% CI 0.16 to 0.68) and significantly less likely to report checking the temperature of every bath (RR 0.84, 95% CI 0.73 to 0.97). Seven (15%) intervention arm families reported problems with their TMV. CONCLUSIONS: TMVs and accompanying educational leaflets are effective at reducing bath hot tap water temperatures in the short and longer term and are acceptable to families. Housing providers should consider fitting TMVs in their properties and legislators should consider mandating their use in refurbishments as well as in new builds.
机译:目的:评估恒温混合阀(TMV)在减少浴热自来水温度下的有效性,评估TMV对家庭的可接受性和对浴时间安全实践的影响。设计:务实平行臂随机控制试验。环境:英国苏格兰格拉斯哥的社会住房组织。参与者:124个家庭,至少有一个5岁以下的儿童。干预:在TMV配件之前和时,由合格的水管工和教育传单装配的TMV。主要观察措施:沐浴热自来水温度为3个月和12个月后干预后或随机化,可接受性,TMV和洗澡时间安全实践的问题。结果:干预臂家庭在3个月的3个月和12个月的后续行动中具有明显较低的浴室热水温度,而不是控制臂中的家庭(3个月:干预臂中位45.0摄氏度,控制ARM中位56.0度C,差异中位数,-11.0,95%CI -14.3至-7.7); 12个月:干预臂中位数46.0摄氏度,控制臂中位数55.0摄氏度,中位数差异-9.0,95%CI -11.8至-6.2)它们显着更有可能对他们的浴热水温度感到高兴或非常满意( RR 1.43,95%CI 1.05至1.93),显着不太可能将温度报告为太热(RR 0.33,95%CI 0.16至0.68),并且报告每种浴室的温度明显不太可能(RR 0.84,95 %CI 0.73至0.97)。七(15%)干预ARM家庭报告其TMV问题。结论:TMV和随附的教育传单在短期和长期内减少浴热自来水温度,并且是家庭可接受的。住房提供商应考虑在其财产和立法者中拟合TMV,应考虑授权其在翻新以及新建中的使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号