...
首页> 外文期刊>Applied immunohistochemistry and molecular morphology: AIMM >The Use of CYFRA 21 -1 for the Detection of Breast Cancer Axillary Lymph Node Metastases in Needle Washouts of Fine-Needle Aspiration Biopsies
【24h】

The Use of CYFRA 21 -1 for the Detection of Breast Cancer Axillary Lymph Node Metastases in Needle Washouts of Fine-Needle Aspiration Biopsies

机译:用CyFRA 21 -1检测细针穿刺活检的针垫中的乳腺癌腋窝淋巴结转移

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Background: In the preoperative setting of breast cancer, fine-needle aspiration biopsy (FNAB) guided by ultrasonography can be used to detect axillary lymph node metastases. The aim of the current study was to determine whether measurement in needle washouts of CYFRA 21-1, a soluble fragment of cyto-keratin 19 (CK19), can improve the diagnosis of lymph node tumor deposits. Materials and Methods: Our prospective study included 329 breast cancer patients eligible for a sentinel node procedure. Eighty-two patients had a ultrasonography-guided FNAB of an abnormal or suspicious axillary node and were included in the current analysis. Samples were processed with smears and cell-block histology; afterwards, needles were washed with saline solution, and the CYFRA 21-1 content in the washouts was measured. The cutoff value for positive samples that expressed CK19, as shown by their immunohistochemistry, was determined by a receiver operating characteristic curve. On the basis of this value, the specificity and the sensitivity, as well as the positive and negative predictive values, were then calculated using cytology results as a reference standard. Results: Of the 82 axillary lymph nodes sampled, 61 were positive on cytology and were metastatic for breast cancer, as confirmed by surgery. The median CYFRA 21-1 concentration of positive samples was 88.94ng/mL, whereas in the 21 negative nodes, its median concentration was 1.02ng/mL (P < 0.0001). A CYFRA 21-1 cutoff value of 1.98ng/mL, obtained by the receiver operating characteristic curve, was able to clearly separate negative from positive samples and gave the test a sensitivity of 0.98 and a specificity of 1.00. Positive and negative predictive values were 1.00 and 0.95, respectively. Conclusions: The measurement of CYFRA 21-1 levels in needle washouts after axillary lymph node FNABs represents an accurate, sensitive, and highly predictive procedure in detecting metastatic deposits of breast cancer and is fit to complement cytology and CK19 immunohistochemistry as a diagnostic tool.
机译:背景:在乳腺癌的术前设定中,超声检查引导的细针吸气活检(FNAB)可用于检测腋窝淋巴结转移。目前研究的目的是确定CYFRA 21-1的针垫中的测量,CYTO-keratin 19(CK19)的可溶性片段,可以改善淋巴结肿瘤沉积物的诊断。材料和方法:我们的前瞻性研究包括329名患有Sentinel节点程序的乳腺癌患者。八十二名患者具有异常或可疑腋窝节点的超声引导FNAB,并包括在当前分析中。用涂片和细胞嵌段组织学加工样品;然后,用盐水溶液洗涤针,测量损伤中的CYFRA 21-1含量。表达CK19的正样品的截止值由其免疫组织化学所示,通过接收器操作特性曲线确定。根据该值,然后使用细胞学结果作为参考标准计算特异性和敏感性,以及阳性和阴性预测值。结果:82例腋窝淋巴结进行取样,61个细胞学阳性,乳腺癌转移,由手术证实。阳性样品的中值Cyfra 21-1浓度为88.94ng / ml,而在21个阴性节点中,其中值浓度为1.02ng / ml(p <0.0001)。通过接收器操作特征曲线获得的1.98ng / ml的CyFRA 21-1截止值,能够清楚地与阳性样品分离阴性,并给出测试的灵敏度为0.98和1.00的特异性。正面和负面预测值分别为1.00和0.95。结论:在腋窝淋巴结FNABs后针状洗涤剂中CyFRA 21-1水平的测量代表了检测乳腺癌转移性沉积的准确,灵敏和高度预测的过程,并适合将细胞学和CK19免疫组织化为诊断工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号