Determination of retinyl palmitate in ointment by HPLC with diode array detection.

机译:高效液相色谱-二极管阵列检测法测定软膏中棕榈酸视黄酯的含量。

获取原文
获取原文并翻译 | 示例
           

摘要

A simple and rapid HPLC with diode array detection method was developed for the determination of retinyl palmitate present together with other active substances in an ointment. Chromatographic separation was performed on 100 RP-18 Lichrospher column of particle size 5 microm. The mobile phase was methanol:water (98:2, v/v) and flow rate was 2.0 mL/min in isocratic mode. Samples were analyzed for 30 min. Spectophotometric detection was conducted at 325 nm. Under these conditions, the method featured high sensitivity, good precision and comparability of results as proven by the method validation and statistical analysis of the results. The limits of detection and determination were 0.4317 mg/100 mL and 1.3081 mg/100 mL, respectively, recovery values were measured at three levels 80%, 100% and 120% and yielded 101.05%, 101.34% and 100.43%, respectively. The linearity range was checked from 2 mg/100 mL to 10 mg/100 mL. The precision and inter-day precision of the method was expressed by relative standard deviation value and did not exceed 1.68%.
机译:开发了一种简单快速的带有二极管阵列检测方法的HPLC,用于测定软膏中与其他活性物质一起存在的棕榈酸视黄酯。在粒径为5微米的100 RP-18 Lichrospher色谱柱上进行色谱分离。流动相为甲醇:水(98:2,v / v),等度模式下流速为2.0 mL / min。分析样品30分钟。分光光度法检测是在325 nm处进行的。在这些条件下,该方法具有高灵敏度,良好的精密度和结果可比性的特点,方法验证和结果统计分析证明了这一方法。检出限和测定限分别为0.4317 mg / 100 mL和1.3081 mg / 100 mL,分别在80%,100%和120%的三个水平上测定了回收率,分别得到了101.05%,101.34%和100.43%。线性范围为2 mg / 100 mL至10 mg / 100 mL。该方法的精密度和日间精密度用相对标准偏差值表示,不超过1.68%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号