Importance of over‐reading ambulatory ECG‐based microvolt T‐wave alternans to eliminate three main sources of measurement error

机译:过度读取的基于动态ECG的微伏T波替波的重要性消除了三个主要测量误差源

获取原文
获取原文并翻译 | 示例

摘要

Abstract Background Ambulatory electrocardiogram (ECG)‐based microvolt T‐wave alternans values measured by the modified moving average method (MMA‐TWA) can be disrupted by T‐wave changes that mimic true repolarization alternans. Methods We investigated potential sources of measurement error by studying 19 healthy subjects (12 men; median age, 25) free of known heart disease with 36‐month follow‐up to establish freedom from significant arrhythmia or syncope. All participants underwent 24‐hr continuous 12‐lead ECG monitoring. Causes of automated MMA‐TWA ≥42?μV episodes were classified based on visual inspection. Results A total of 2,189 episodes of automated MMA‐TWA episodes ≥42?μV were observed in all subjects (peak MMA‐TWA: median, 94?μV; interquartile range, 81–112?μV). All episodes included one or more beats with T‐wave deformation which lacked “repeating ABAB pattern” and therefore were identified as TWA measurement error. Causes of such error were categorized as: (a) artifact [72.6% (1,589/2,189), observed in 19 (100%) subjects], more frequently in limb than precordial leads; (b) T‐wave changes due to changes in heart/body position [25.5% (559/2,189), observed in 14 (73.7%) subjects], frequently observed in leads V1‐2; and (c) postextrasystolic T‐wave changes [1.9% (41/2,189), observed in 2 (10.5%) subjects]. Conclusions Relying only on automated MMA‐TWA values obtained during ambulatory ECG monitoring can lead to incorrect measurement of TWA. Our findings offer the potential to reduce false‐positive TWA results and to achieve more accurate detection of true repolarization alternans.
机译:摘要通过修改的移动平均法(MMA-TWA)测量的基于改进的移动平均方法(MMA-TWA)测量的动态心电图(ECG)的微电压仪(MMA-TW)的变化可能被用于模拟真正的倒波的变化。方法通过研究19个健康科目(12名男性;中位数年龄,25个),从36个月的随访中,通过学习19个健康的科目(12名男性,25个)来调查潜在的测量误差来源。所有参与者都经历了24小时连续的12-Lead ECG监测。基于目视检查,分类了自动MMA-TWA≥42Ω·μV剧集的原因。结果在所有受试者中观察到总共2,189个自动化MMA-TWA发作≥42μV(峰值MMA-TWA:中值,94ΩμV;四分位数范围,81-112μV)。所有剧集包括一个或多个具有T波形变形的节拍,缺少“重复ABAB模式”,因此被识别为TWA测量误差。这些误差的原因被分类为:(a)工件[72.6%(1,589 / 2,189),在19(100%)受试者中观察到,比前沿引线更常见; (b)由于心脏/体位的变化导致的T波变化[25.5%(559 / 2,189),观察到14个(73.7%)受试者],经常在引线V1-2中观察; (c)脱右糊精T波变化[1.9%(41 / 2,189),在2(10.5%)受试者中观察]。结论仅依赖于在动态ECG监测期间获得的自动MMA-TWA值可能导致TWA的测量不正确。我们的研究结果提供了减少假阳性TWA结果的可能性,并实现更准确地检测真正的真正的倒钩。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号