In this report, a simple chemiluminescence (CL) approach for detecting an anionic dye, alizarin red S (ARS), based on layered double hydroxides (LDHs)-improved CL from hydrogen peroxide (H2O2) and luminol system is proposed. The LDHs-improved H2O2-luminol CL is due to the adsorption of luminol dianion and peroxide anion onto the positively charged brucite-like layers and the facilitated formation of carbonate radicals, which benefits the generation of light-emitting intermediate 3-aminophthalate anions. Notably, the LDHs-improved H2O2-luminol CL signal is markedly restrained in the presence of ARS, which is assigned to the ARS-mediated occupation of the positively charged centres on the brucite-like layers and the inhibition of the formation of 3-aminophthalate anions. Thus, a facile CL method for ARS perception based on the suppression effect of ARS toward the LDHs-improved H2O2-luminol CL has been developed. This simple CL approach shows a limit of detection of 0.1 mM toward ARS and exhibits a linear response in the concentration range from 0.5 to 30 mM. In addition, the proposed method exhibits a high specificity toward ARS over other small molecules, metal ions or anions. Furthermore, the practical application of the proposed method for ARS sensing is evaluated with the dye wastewater samples.
机译:在本报告中,提出了一种基于层状双氢氧化物(LDHS) - 来自过氧化氢(H2O2)和Luminol系统的基于层状双氢氧化物(LDHS)和鲁米诺系统的用于检测阴离子染料的简单化学发光(CL)方法。 LDHS改进的H 2 O 2-Luminol Cl是由于鲁米诺脱叶和过氧化物阴离子的吸附到正电荷的布鲁氏石层和碳酸酯基团的促进形成,这有利于发光中间体3-氨基邻苯二甲酸酯阴离子。值得注意的是,LDHS改善的H 2 O 2-鲁米诺CL信号在存在的ARS存在下明显抑制,其分配给ARS介导的占用型中心带电中心的占据型号的层,以及抑制3-氨基邻氨基酸盐的形成阴离子。因此,已经开发了基于ARS朝向LDHS改进的H2O2-Luminol CL的ARS抑制效果的ARS感知的容易CL方法。这种简单的CL方法显示了朝向ARS 0.1mm的检测限,并且在0.5至30mm的浓度范围内表现出线性响应。此外,所提出的方法对其他小分子,金属离子或阴离子具有高特异性。此外,用染料废水样品评价所提出的ARS感测方法的实际应用。

著录项

  • 来源
    《Analytical methods》 |2017年第46期|共6页
  • 作者单位

    Henan Normal Univ Key Lab Yellow River &

    Huai River Water Environm Henan Key Lab Environm Pollut Control Sch Environm Minist Educ Xinxiang 453007 Henan Peoples R China;

    Henan Normal Univ Key Lab Yellow River &

    Huai River Water Environm Henan Key Lab Environm Pollut Control Sch Environm Minist Educ Xinxiang 453007 Henan Peoples R China;

    Beijing Univ Chem Technol State Key Lab Chem Resource Engn Beijing 100029 Peoples R China;

    Beijing Univ Chem Technol State Key Lab Chem Resource Engn Beijing 100029 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号