首页> 外文期刊>Analytical methods >A novel competitive-displacement fluorescence assay for L-penicillamine based on the reaction between the target and N-acetyl-L-cysteine-capped CdTe quantum dots for copper ions
【24h】

A novel competitive-displacement fluorescence assay for L-penicillamine based on the reaction between the target and N-acetyl-L-cysteine-capped CdTe quantum dots for copper ions

机译:基于铜离子的靶和N-乙酰基-1-半胱氨酸封装的CdTe量子点与N-乙酰基-1-半胱氨酸封闭的CdTe量子点之间的新型竞争性偏移荧光测定

获取原文
获取原文并翻译 | 示例
           

摘要

D-Penicillamine (d-PA), as the dominant enantiomer, is usually used in many clinical drugs, but the other enantiomer, l-penicillamine (l-PA) is a toxic enantiomer. Therefore, it is of great significance to analyze and detect l-PA in biomedical or environmental samples. CdTe quantum dots (CdTe QDs) were modified by N-acetyl-l-cysteine (NALC) as novel fluorescent probes and were successfully utilized for the determination of l-penicillamine. The fluorescence of the CdTe QDs decreased significantly in the presence of cupric ions (Cu2+) due to the binding of Cu2+ to NALC on the surface of the CdTe QDs, but the addition of l-PA immediately resulted in efficient fluorescence recovery of the modulated CdTe QDs. The experimental results showed that the pH of the buffer solution and the concentration of Cu2+ affected the fluorescence intensity upon adding l-PA. Under the optimum conditions, the recovered fluorescence intensity was linearly proportional to the increasing l-PA concentration in the range of 2 x 10(-7) to 4 x 10(-6) mol L-1, with correlation coefficient R-2 = 0.9980. So, a new, simple and rapid method for the determination of l-PA has been developed and its potential has been demonstrated in human serum samples and environmental samples with satisfactory results.
机译:作为优势对映体的D-青霉胺(D-PA)通常用于许多临床药物,但另一个对映体L-青霉胺(L-PA)是毒性映体。因此,在生物医学或环境样品中分析和检测L-PA具有重要意义。通过N-乙酰-1-半胱氨酸(NALC)改性CDTE量子点(CDTE QDS)作为新型荧光探针,并成功地用于测定L-青霉胺。由于Cu 2 +至NALC的结合在CDTE QDS的表面上,CDTE QD的荧光显着降低,但是加入L-PA立即产生调制CDTE的有效荧光恢复QD。实验结果表明,缓冲溶液的pH和Cu2 +的浓度影响了加入L-PA时的荧光强度。在最佳条件下,回收的荧光强度与增加的L-PA浓度在2×10( - 7)至4×10(-6)摩尔L-1的范围内线性成比例,相关系数R-2 = 0.9980。因此,已经开发出一种新的,简单而快速的测定L-PA的方法,并且其潜力已经在人血清样本和环境样品中进行了令人满意的结果。

著录项

  • 来源
    《Analytical methods》 |2018年第19期|共9页
  • 作者单位

    Chongqing Three Gorges Univ Key Lab Water Environm Evolut &

    Pollut Control Go Chongqing 404100 Peoples R China;

    Chongqing Three Gorges Univ Key Lab Water Environm Evolut &

    Pollut Control Go Chongqing 404100 Peoples R China;

    Chongqing Three Gorges Univ Key Lab Water Environm Evolut &

    Pollut Control Go Chongqing 404100 Peoples R China;

    Chongqing Three Gorges Univ Key Lab Water Environm Evolut &

    Pollut Control Go Chongqing 404100 Peoples R China;

    Chongqing Three Gorges Univ Key Lab Water Environm Evolut &

    Pollut Control Go Chongqing 404100 Peoples R China;

    Chongqing Three Gorges Univ Key Lab Water Environm Evolut &

    Pollut Control Go Chongqing 404100 Peoples R China;

    Chongqing Three Gorges Univ Key Lab Water Environm Evolut &

    Pollut Control Go Chongqing 404100 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号