A novel magnetic solid-phase extraction (MSPE) method applying a nanosorbent based on an Ni-Al layered double hydroxide/magnetite nano-hybrid (Ni-Al LDH/Fe3O4) was developed for the preconcentration and speciation of Mn(VII)/Mn(II) in aqueous solutions via flame atomic absorption spectrometry. The synthesized Ni-Al LDH/Fe3O4 nano-hybrid was characterized via X-ray diffraction, Fourier transform infrared spectrometry, scanning electron microscopy and energy dispersive X-ray spectroscopy. The prepared nanosorbent can selectively extract Mn(VII) ions due to the negative charge of MnO4-ions. The total Mn and thus indirectly Mn(II) were determined after pre-oxidation of Mn(II) to Mn(VII) with an acidic solution of potassium periodate. Various parameters affecting the extraction recovery such as the amount of Ni-Al LDH/Fe3O4 nano-hybrid, pH of the solution, extraction time, eluent conditions, sample volume and interfering ions were investigated. Applying the optimum conditions, the developed method was successfully used for the speciation of Mn(VII)/Mn(II) species in various water samples with a linear dynamic range of 0.4-150 ng mL(-1) (R-2 = 0.9998) and a detection limit of 0.1 ng mL(-1). The method precision was evaluated with six replicates at a concentration level of 80 ng mL(-1), and a relative standard deviation of 3.3% was obtained. Furthermore, the method was applied for the determination of Mn(VII)/Mn(II) species in spiked real water samples and relative recoveries in the range of 93.6% to 103.3% were obtained.
机译:施用基于Ni-Al层层双氢氧化物/磁铁矿纳米杂交物(Ni-Al LDH / Fe3O4)的新型磁性固相萃取(MSPE)方法用于Mn(VII)/ Mn的前浓缩和形态(ii)通过火焰原子吸收光谱法在水溶液中。通过X射线衍射,傅里叶变换红外光谱法,扫描电子显微镜和能量分散X射线光谱表征合成的Ni-Al LDH / Fe3O4纳米杂化。制备的纳米吸收剂可以选择性地提取由于MnO 4 - 离子的负电荷引起的Mn(VII)离子。在用钾碘酸钾的酸性溶液将Mn(II)预氧化至Mn(VII)后测定总Mn和因此间接Mn(II)。研究了影响提取恢复的各种参数,例如Ni-Al LDH / Fe3O4纳米杂种,溶液的pH,提取时间,洗脱条件,样品体积和干扰离子的量。应用最佳条件,在各种水样中成功地成功地用于各种水样中的Mn(VII)/ Mn(II)种类的物种,线性动态范围为0.4-150ng mL(-1)(R-2 = 0.9998 )和检出极限为0.1ng ml(-1)。在浓度水平为80ng ml(-1)的六种重复中评价方法精度,得到3.3%的相对标准偏差。此外,施用该方法用于测定掺入的真实水样中的Mn(VII)/ Mn(II)物种,得到93.6%至103.3%的相对回收率。

著录项

  • 来源
    《Analytical methods》 |2019年第4期|共10页
  • 作者单位

    Azarbaijan Shahid Madani Univ Fac Sci Dept Chem 35 Km Tabriz Marageh Rd POB 53714-161 Tabriz 5375171379 Iran;

    Azarbaijan Shahid Madani Univ Fac Sci Dept Chem 35 Km Tabriz Marageh Rd POB 53714-161 Tabriz 5375171379 Iran;

    Azarbaijan Shahid Madani Univ Fac Sci Dept Chem 35 Km Tabriz Marageh Rd POB 53714-161 Tabriz 5375171379 Iran;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号