首页> 外文期刊>American Journal of Infection Control >Use of adenosine triphosphate to audit reprocessing of flexible endoscopes with an elevator mechanism
【24h】

Use of adenosine triphosphate to audit reprocessing of flexible endoscopes with an elevator mechanism

机译:用电梯机构审计腺苷三磷酸腺苷的使用,审计柔性内窥镜的再循环

获取原文
获取原文并翻译 | 示例

摘要

BackgroundThere have been reported outbreaks of carbapenem-resistant Enterobacteriaceae infections linked to endoscopes with elevator mechanisms. Adenosine triphosphate (ATP) testing has been used as a marker for bioburden and monitoring manual cleaning for flexible endoscopes with and without an elevator mechanism. The objective of this study was to determine whether routine ATP testing could identify areas of improvement in cleaning of endoscopes with an elevator mechanism. MethodsATP testing after manual cleaning of TJF-Q180V duodenoscopes and GF-UCT180 linear echoendoscopes (Olympus America Inc, Center Valley, PA) was implemented. Samples were tested from the distal end, the elevator mechanism, and water flushed through the lumen of the biopsy channel. Data were recorded and compared by time point, test point, and reprocessing technician. ResultsOverall failure rate was 6.99% (295 out of 4,219). The highest percentage of failed ATP tests (17.05%) was reported in the first quarter of routine testing, with an overall decrease in rates over time. The elevator mechanism and working channel lumen had higher failure rates than the distal end. Quality of manual cleaning between reprocessing technicians showed variation. ConclusionATP testing is effective in identifying residual organic material and improving quality of manual cleaning of endoscopes with an elevator mechanism. Cleaning efficacy is influenced by reprocessing technicians and location tested on the endoscope. Close attention to the working channel and elevator mechanism during manual cleaning is warranted.
机译:背景技术报告爆发了与电梯机制有关的Carbapenem抗性肠杆菌痤疮膜感染。腺苷三磷酸(ATP)测试已被用作Bioburden和监测手动清洗的标记,用于柔性内窥镜,具有升降机机构。本研究的目的是确定常规ATP测试是否可以识别用电梯机制清洁内窥镜的改善领域。 MethodsATP检测在手动清洁TJF-Q180V Duodenoscepes和GF-UCT180线性echoencopes(Olympus America Inc,Center Valley,PA)后进行了实施。从远端,电梯机构和水冲过活检通道的内腔进行样品。通过时间点,测试点和再处理技术人员记录和比较数据。结果失败率为6.99%(295分,为4,219)。在常规测试的第一季度报告了最高的ATP测试(17.05%)的最高百分比,随着时间的推移,速度的总体下降。电梯机构和工作通道腔具有比远端更高的故障率。后处理技术人员手动清理的质量表现出变化。结论采用电梯机构识别残留有机材料,可有效地识别残留有机材料,提高内窥镜的手工清洁质量。清洁效能受重新处理技术人员和在内窥镜上测试的位置的影响。在手动清洁期间密切关注工作通道和电梯机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号