...
首页> 外文期刊>American Journal of Orthodontics and Dentofacial Orthopedics >Expansion with transpalatal arch or continuous arch mechanics
【24h】

Expansion with transpalatal arch or continuous arch mechanics

机译:扩展与转座拱门或连续拱门力学

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: This study aimed to compare the 3-dimensional force system produced by transpalatal arch (TPA) mechanics with that produced by a continuous arch (CA) on the expansion of maxillary first molars. Methods: A patient's model with 2 molars in 4-mm crossbite had orthodontic appliances bonded to all teeth. The first and the second molars were connected to two 3-dimensional load cells to compare the forces in the transverse and anteroposterior planes (Fx and Fy) and the rotational moments (Mz) produced in both molars by the expanded TPA and by 0.016-in nickel-titanium CA. The data were evaluated using 6 independent t tests, and the net moment at the molar's center of resistance was also calculated. Results: All forces and moments were different at both molars. At the first molar, CA produced Fx of 2.60 N, Fy of -0.08 N, Mz of -5.16 N.mm, and Net Mz of -5.68 N.mm, whereas the TPA produced Fx of 2.87 N, Fy of -0.60 N, Mz of -22.08 N.mm, and Net Mz of -25.09 N.mm. At the second molar, the TPA did not produce significant forces and moments, whereas the CA produced Fx of -1.00 N, Mz of 3.95 N.mm, Fy of -0.84 N, and Net Mz of -0.67 N.mm. Conclusions: Based on our findings in a clinical set up with the specific horseshoe TPA and archwire tested, with the TPA used only on the first molars and the CA used from one second molar to the other, the mechanics produced different expansion forces at the first molar. The TPA produced a larger rotational side effect on the first molar, whereas the CA produced side effects on the second molar.
机译:介绍:本研究旨在比较通过连续拱(CA)产生的Transpalatal Arch(TPA)力学产生的三维力系统在上颌第一磨牙的膨胀。方法:患者的4毫米杂交中有2磨牙的患者模型与所有牙齿都有正畸的家电。第一和第二磨牙连接到两个三维负载电池,以将横向和前后平面(FX和FY)中的力和通过膨胀的TPA和0.016℃的摩尔产生的旋转矩(MZ)进行比较。镍钛奶油。使用6个独立的T测试评估数据,还计算了摩尔电阻中心的净时刻。结果:两种臼齿的所有力和时刻都不同。在第一磨牙中,CA产生的FX为2.60 n,FY为-0.08 n,mz -5.16 n.mm,净mz为-5.68 n.mm,而TPA产生的fx为2.87 n,fy为-0.60 n ,Mz的-22.08 n.mm,净mz为-25.09 n.mm。在第二磨牙中,TPA没有产生显着的力量和矩,而CA产生的FX为-1.00n,Mz为3.95 n.mm,fy -0.84 n,净mz为-0.67 n.mm。结论:基于我们在用特定马蹄TPA和archwire测试的临床设置中的研究结果,仅使用从第一磨牙和从一个第二磨牙使用的第一个臼齿和CA中使用的TPA,在第一个机械产生不同的膨胀力磨牙。 TPA对第一磨牙产生较大的旋转副作用,而CA对第二摩尔产生的副作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号