摘要

Introduction: The aim of this study was to evaluate and compare the clinical success of 2 lingual retainer wires. Methods: The 120 patients included in the study were divided into 2 groups randomly. In group 1, 0.0175-in 6-strand stainless steel wire (Ortho Technology, Lutz, Fla) was used, the lingual retainers were fabricated on plaster models, and a silicon transfer key was used. In group 2, 0.0195-in dead-soft coaxial wire (Respond; Ormco, Orange, Calif) was used, and the lingual retainers were fabricated directly in the patient's mandibular arch without a study model. Pretreatment, posttreatment, and posttreatment 3-month, 6-month, 9-month, and 12-month 3-dimensional orthodontic models were evaluated. Failure rates, mandibular arch irregularity values, intercanine distances, and arch lengths were compared. Results: The clinical bond failure rates were 13.2% for the 0.0175-in 6-strand stainless steel wire and 18.9% for the 0.0195-in dead-soft wire. The difference in bond failures between the 2 groups was not statistically significant. There was a statistically significant increase in mandibular arch irregularity in both groups during the 12-month follow-up. However, the increase was significantly higher in the second group than in the first one. Furthermore, the intercanine distance decreased over time in the second group. Conclusions: Our findings regarding mandibular arch measurements indicate that fabrication of lingual retainers can be more safely accomplished with 0.0175-in 6-strand stainless steel wire than with 0.0195-in dead-soft coaxial wire.
机译:简介:本研究的目的是评估和比较2个舌套线的临床成功。方法:将该研究中包含的120名患者随机分为2组。在第1组中,使用了0.0175英寸的6股不锈钢线(Ortho Technology,Lutz,FLA),在石膏模型上制造了舌保持器,使用硅转移键。在第2组中,使用了0.0195-在死去的柔软同轴线(响应; Ormco,Orange,Calif),并且在没有研究模型的情况下直接在患者的下颌拱门中制造舌置。评估预处理,后治疗和后期3个月,6个月,9个月和12个月的3维正畸模型。比较了故障率,下颌拱形不规则值,桦木距离和拱长。结果:0.0175英寸6股不锈钢线的临床粘结失效率为13.2%,为0.0195 - 钻孔软线的18.9%。 2组之间的债券失败差异在统计学上没有统计学意义。在12个月的随访期间,两组下颌弓不规则性统计学上显着增加。然而,第二组的增加显着高于第一组。此外,第二组中的白桦距离随着时间的推移而降低。结论:关于下颌拱测量的研究结果表明,舌置静止器的制造比0.0175英寸的6股不锈钢线,而不是0.0195在死钝的同轴线上。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号