首页> 外文期刊>American Journal of Ophthalmology: The International Journal of Ophthalmology >Distinguishing Keratoconic Eyes and Healthy Eyes Using Ultrahigh-Resolution Optical Coherence Tomography–Based Corneal Epithelium Thickness Mapping
【24h】

Distinguishing Keratoconic Eyes and Healthy Eyes Using Ultrahigh-Resolution Optical Coherence Tomography–Based Corneal Epithelium Thickness Mapping

机译:使用超高分辨率光学相干断层扫描的角膜上皮厚度测绘来区分角截止眼睛的眼睛和健康的眼睛

获取原文
获取原文并翻译 | 示例
           

摘要

PurposeTo find differences in epithelial thickness (ET) maps of eyes with keratoconus (KC) and healthy eyes. DesignInstitutional cross-sectional study. MethodsIn this study 40 keratoconic eyes and 76 healthy eyes were scanned using a custom-built ultrahigh-resolution optical coherence tomography system. Automated segmentation ET maps with 17 subsectors were calculated (central, temporal inferior, temporal superior, nasal inferior, and nasal superior area). The thinnest point of the epithelium (minET), the thickest point of the epithelium (maxET), and the thinnest point diagonally opposing the thickest point (ETmax/op) were additional parameters. Ratios were calculated as follows: minET/diagonally opposing point (R1), maxET/diagonally opposing point (R2), inferior temporal area/superior nasal area (RTI/NS), and inferior/superior hemisphere (RI/S). Furthermore, collected parameters were analyzed regarding their diagnostic accuracy (area under the curve; AUC). ResultsStatistically significant differences were as follows: central ET, 46.25 ± 2.56/50.91 ± 1.66; minET, 38.50 ± 2.10/46.79 ± 1.27; ETmax/op, 47.14 ± 2.45/49.60 ± 1.57; temporal inferior area: 43.93 ± 2.95/51.04 ± 1.51 (all mean ± standard deviation, μm); R1, 0.76 ± 0.09/0.93 ± 0.04; R2, 1.08 ± 0.04/1.21 ± 0.16; RTI/NS, 0.85 ± 0.08/1.02 ± 0.04; RI/S: 0.92 ± 0.07/0.99 ± 0.02. AUC values were R1: 0.979 (confidence interval [CI]: 0.957–1.000), RTI/NS: 0.977 (CI: 0.951–1.000), and minET: 0.928 (CI: 0.880–0.977). ConclusionsEpithelial thickness maps could clearly visualize different ET patterns. Parameters with the highest potential of diagnostic discrimination between eyes with KC and healthy eyes were, in descending order, R1, RTI/NS, and minET. Consequently, epithelial thickness irregularity and asymmetry seem to be the most promising diagnostic factor in terms of discriminating between keratoconic eyes and healthy eyes.
机译:purposeto发现上皮厚度(et)眼睛映射与角蛋白(kc)和健康的眼睛。 DesignInstityal横截面研究。方法使用定制的超高分辨率光学相干断层扫描系统扫描40项研究40个角质蹄型眼睛和76个健康的眼睛。计算具有17个分割器的自动分段ET地图(中央,时间下,颞级,鼻劣,鼻腔高级区域)。上皮(minet)的最薄点,上皮(maxet)的最厚点,以及较厚点对角线(etmax / op)的最薄点是附加参数。比率计算如下:minet /对角相对点(R1),maxet /对比相对点(R2),较差的颞区/优越的鼻区域(Rti / ns)和劣质/优越的半球(Ri / s)。此外,分析收集的参数关于它们的诊断准确性(曲线下的区域; AUC)。结果显着差异如下:ET,46.25±2.56 / 50.91±1.66; Minet,38.50±2.10 / 46.79±1.27; Etmax / OP,47.14±2.45 / 49.60±1.57;时间下面积:43.93±2.95 / 51.04±1.51(所有平均值±标准偏差,μm); R1,0.76±0.09 / 0.93±0.04; R2,1.08±0.04 / 1.21±0.16; RTI / NS,0.85±0.08 / 1.02±0.04; RI / S:0.92±0.07 / 0.99±0.02。 AUC值为R1:0.979(置信区间[CI]:0.957-1.000),RTI / NS:0.977(CI:0.951-1.000)和Minet:0.928(CI:0.880-0.977)。结论精神厚度图可以清晰可视化不同的ET模式。具有KC和健康眼睛之间的眼睛之间诊断辨别潜力最高的参数是下降阶,R1,RTI / NS和Minet。因此,上皮厚度不规则性和不对称性似乎是鉴别角灭绝眼睛和健康眼睛之间的鉴定性最有前景的诊断因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号