BACKGROUND AND PURPOSE: The hypothesis that MS could be provoked by a derangement of the blood outflow from the brain has been largely discredited. In part, it was because data on the normal pattern of outflow are scarce and obtained with different methods. The aim of this study was to evaluate the normal pattern of outflow for the vertebral and internal jugular veins in healthy subjects with multigate color Doppler. MATERIALS AND METHODS: Twenty-five volunteers were studied to assess vessel area, mean velocity, and flow for the vertebral and internal jugular veins in the supine and sitting positions. RESULTS: In the sitting position, flow decreases, both in vertebral veins and internal jugular veins, as the total vessel area decreases (from 0.46 ± 0.57 to 0.09 ± 0.08 cm2), even if the mean velocity increases (from 12.58 ± 10.19 to 24.14 ± 17.60 cm/s). Contrary to what happens to the blood inflow, outflow in the supine position, through vertebral and internal jugular veins, is more than twice the outflow in the sitting position (739.80 ± 326.32 versus 278.24 ± 207.94 mL/min). In the sitting position, on application of very low pressure to the skin with the sonography probe, internal jugular veins rarely appear to occlude. A pronounced difference of diameter between internal jugular veins was present in approximately one-third of subjects. CONCLUSIONS: Our results support the view that other outflow pathways, like the vertebral plexus, play a major role in the normal physiology of brain circulation and must be assessed to obtain a complete picture of blood outflow.
机译:背景和目的:假设MS可以通过大脑血液流出的紊乱而引发的假设已经很大程度上不信任。部分原因是因为流出的正常模式的数据是稀缺的并且用不同的方法获得。本研究的目的是评估具有多相色彩多普勒的健康受试者中椎体和内部颈静脉的正常流出模式。材料和方法:研究了二十五个志愿者,评估仰卧和坐姿的椎体和内部颈静脉的血管面积,平均速度和流动。结果:在坐姿,流量减少,椎体静脉和内部颈静脉,随着总血管面积降低(从0.46±0.57至0.09±0.08cm 2),即使平均速度增加(从12.58±10.19至24.14 ±17.60cm / s)。与血液流入发生的情况相反,仰卧位的流出,通过椎体和内部颈静脉,坐姿的流出量超过226.32与278.24±207.94 ml / min的两倍。在坐姿,在用超声探针施加对皮肤的非常低压时,内部颈静脉很少似乎堵塞。在约三分之一的受试者中存在内部颈静脉之间的直径明显差异。结论:我们的结果支持认为其他流出途径,如椎体丛,在脑循环正常生理中发挥重要作用,并且必须评估以获得血液流出的完整图像。

著录项

  • 来源
  • 作者单位

    SOD Medicina Interna Ad Orientamento all'Alta Complessitǎ Assistenziale 3 Dipartimento Del Cuore e;

    Dipartimento di Medicina Interna e di Urgenza SOD Valutazione Cardiologica Dipartimento Del Cuore;

    Esaote S.p.A. Firenze Italy;

    SOD Medicina Interna Ad Orientamento all'Alta Complessitǎ Assistenziale 3 Dipartimento Del Cuore e;

    SOD Medicina Interna Ad Orientamento all'Alta Complessitǎ Assistenziale 3 Dipartimento Del Cuore e;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 放射医学;
  • 关键词

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号