The data resulting from the thermal-hydraulic test of the ITER TF CICC are used to determine the flow partition and the overall effective heat transfer coefficient (h(BC)) between bundle and central channel in a direct way, i.e. by analysis of the heat transfer between both flow channels, based on the mass and energy balance equations and the readings of thermometers located inside the cable. In cases without a local heat source in the considered cable segment the obtained h(BC) values were consistent with those obtained in earlier studies by analysis of experimental data using indirect methods. It was also observed that the transverse heat transfer was strongly enhanced in a cable segment heated from outside. This phenomenon results from the mass transfer from the bundle region to the central channel. The experimental h(BC) data obtained for the case without a heat source in the considered segment were also compared with those calculated using various heat transfer correlations. (C) 2015 Elsevier Ltd. All rights reserved.
机译:由ITer TF CICC的热液压试验产生的数据用于以直接方式,即通过分析热量的束和中央通道之间的流量分区和整体有效的传热系数(H(BC)),即通过热量分析基于质量和能量平衡方程和位于电缆内部的温度计的读数之间的转移。在所考虑的电缆段中没有局部热源的情况下,所获得的H(BC)值与使用间接方法的实验数据分析先前研究中获得的那些。还观察到,在从外部加热的电缆段中强烈地增强了横向传热。这种现象来自从束区域到中央通道的质量转移。还与使用各种传热相关性计算的那些相比,在没有考虑的区段中没有热源的情况下获得的实验H(BC)数据。 (c)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号