...
首页> 外文期刊>Acta biomaterialia >Changes in corneal thickness, curvature, and anterior chamber depth during the menstrual cycle.
【24h】

Changes in corneal thickness, curvature, and anterior chamber depth during the menstrual cycle.

机译:月经周期期间角膜厚度,曲率和前腔深度的变化。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: To determine the variations in corneal thickness values, keratometry readings, and anterior chamber depths (ACD) during the menstrual cycle of young women using the noncontact Scheimpflug imaging technique. DESIGN: Prospective cohort study. PARTICIPANTS: Fourteen women with regular menstrual cycles who were not taking contraceptive pills were enrolled and had measurements taken every other day during a full menstrual cycle, starting from the first day. None used contact lenses or regular medication, and none had systemic disease or history of eye surgery. METHODS: The thickness at the centre, superior, inferior, temporal, nasal, and thinnest point of the cornea, the keratometry readings, and the ACD values measured with the Pentacam were recorded. We used data on days 1, 3, and 5 of the studied cycle, and counting backwards, 2, 4, 6, 12, 14, and 16 days before the first day of the next cycle. RESULTS: The mean differences between 2 points of time were not statistically significant (p > 0.05) for any variable. The mean difference between any 2 paired thickness measurements was less than 5.0 microm. CONCLUSIONS: Contrary to our expectations and previous findings using ultrasound pachymetry, we found no clinically or statistically significant differences between the repeated measurements with the Pentacam. This could indicate that the Pentacam is a clinical tool with less variability when performing serial measurements and follow-up examinations.
机译:目的:使用非接触式雪松成像技术确定年轻女性的月经周期期间角膜厚度值,腔腔读数和前房深度(ACD)的变化。设计:预期队列研究。参与者:没有服用避孕药的常规月经周期的十四个妇女被纳入并在一天开始,从第一天开始,每隔一天每隔一天进行测量。没有使用隐形眼镜或正规用药,没有有全身性疾病或眼科手术的历史。方法:在角膜的中心,优异的,下,时间,鼻腔和最薄点,角膜测量读数和用戊酰胺测定的ACD值的厚度。我们在研究周期的第1,3和5天使用数据,并在下一个周期的第一天前向后,2,4,6,12,14和16天计算。结果:2个时间点之间的平均差异在任何变量的统计学上没有统计学意义(p> 0.05)。任何2个成对厚度测量值之间的平均差异小于5.0微米。结论:与我们的期望和先前发现使用超声波迷住的预期和先前发现相反,我们在戊酰胺的重复测量之间没有发现临床或统计学上的显着差异。这可能表明,在进行串行测量和后续检查时,致萨克姆是一种临床工具,具有较小的变化。

著录项

  • 来源
    《Acta biomaterialia》 |2010年第1期|共4页
  • 作者单位

    Noor Ophthalmology Research Center Noor Eye Hospital;

    and the Farabi Eye Hospital Tehran University of Medical Sciences Tehran Iran.;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 眼科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号