Characterization of Breast Masses in Digital Breast Tomosynthesis and Digital Mammograms

机译:数字乳房断层合成和数字乳房X线图中乳房肿块的特征

获取原文
获取原文并翻译 | 示例
           

摘要

Rationale and Objectives This study aimed to compare Breast Imaging Reporting and Data System (BI-RADS) assessment of lesions in two-view digital mammogram (DM) to two-view wide-angle digital breast tomosynthesis (DBT) without DM. Materials and Methods With Institutional Review Board approval and written informed consent, two-view DBTs were acquired from 134 subjects and the corresponding DMs were collected retrospectively. The study included 125 subjects with 61 malignant (size: 3.9–36.9?mm, median: 13.4?mm) and 81 benign lesions (size: 4.8–43.8?mm, median: 12.0?mm), and 9 normal subjects. The cases in the two modalities were read independently by six experienced Mammography Quality Standards Act radiologists in a fully crossed counterbalanced manner. The readers were blinded to the prevalence of malignant, benign, or normal cases and were asked to assess the lesions based on the BI-RADS lexicon. The ratings were analyzed by the receiver operating characteristic methodology. Results Lesion conspicuity was significantly higher ( P ? P ?=?.0001) from 0.783 (range: 0.723–0.886) for DM to 0.911 (range: 0.884–0.936) for DBT. Of the 366 ratings for malignant lesions, 343 on DBT and 278 on DM were rated as BI-RADS 4a and above. Of the 486 ratings for benign lesions, 220 on DBT and 206 on DM were rated as BI-RADS 4a and above. On average, 17.8% (65 of 366) more malignant lesions and 2.9% (14 of 486) more benign lesions would be recommended for biopsy using DBT. The inter-radiologist variability was reduced significantly. Conclusion With DBT alone, the BI-RADS assessment of breast lesions and inter-radiologist reliability were significantly improved compared to DM. ]]>
机译:理由和目标本研究旨在将乳房成像报告和数据系统(BI-RAD)进行了两视线数字乳房X线照片(DM)对两视角的广角数字乳房Tomos合成(DBT)进行了评估而没有DM。具有机构审查委员会批准和书面知情同意的材料和方法,从134个受试者获得了双视角的DBT,回顾性地收集了相应的DMS。该研究包括125名受试者,具有61个恶性(尺寸:3.9-36.9?mm,中位数:13.4毫米)和81个良性病变(大小:4.8-43.8?mm,中位数:12.0?mm)和9个正常科目。两种模式中的案例通过六个经验丰富的乳房X线摄影质量标准法,放射科学家以完全交叉的平衡方式读取。读者对恶性,良性或正常情况的患病率蒙蔽,并要求根据Bi-Rads Lexicon评估病变。通过接收器操作特征方法分析评级。结果Lesion Cinapifuity从0.783(范围:0.723-0.886)为DM至0.911(范围:0.884-0.936)的0.783(范围:0.723-0.886)。在DM的DBT和278上的366个对恶性病变的额定值中,额定为Bi-rad 4a及以上。对于良性病变的486个评分,DM上的DBT和206的220级被评定为Bi-rad 4a及以上。平均而言,17.8%(65例366个)更具恶性病变和2.9%(14个中的1466个),使用DBT的活组织检查建议进行良性病变。放射间变异性显着降低。结论单独使用DBT,与DM相比,乳房病变和放射科学间可靠性的Bi-Rad评估显着改善。 ]]>

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号