首页> 外文期刊>Abdominal radiology. >Accuracy and reliability of tablet computer as an imaging console for detection of radiological signs of acute appendicitis using PACS workstation as reference standard
【24h】

Accuracy and reliability of tablet computer as an imaging console for detection of radiological signs of acute appendicitis using PACS workstation as reference standard

机译:平板电脑作为成像控制台的准确性和可靠性,用于使用PACS工作站作为参考标准检测急性阑尾炎的放射性迹象

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To ascertain the accuracy and reliability of tablet as an imaging console for detection of radiological signs of acute appendicitis [on focused appendiceal computed tomography (FACT)] using Picture Archiving and Communication System (PACS) workstation as reference standard. Methods From January, 2014 to June, 2015, 225 patients underwent FACT at our institution. These scans were blindly re-interpreted by an independent consultant radiologist, first on PACS workstation and, two weeks later, on tablet. Scans were interpreted for the presence of radiological signs of acute appendicitis. Accuracy of tablet was calculated using PACS as reference standard. Kappa ( κ ) statistics were calculated as a measure of reliability. Results Of 225 patients, 99 had radiological evidence of acute appendicitis on PACS workstation. Tablet was 100% accurate in detecting radiological signs of acute appendicitis. Appendicoliths, free fluid, lymphadenopathy, phlegmon/abscess, and perforation were identified on PACS in 90, 43, 39, 10, and 12 scans, respectively. There was excellent agreement between tablet and PACS for detection of appendicolith ( к ?=?0.924), phlegmon/abscess ( к ?=?0.904), free fluid ( к ?=?0.863), lymphadenopathy ( к ?=?0.879), and perforation ( к ?=?0.904). Conclusions Tablet computer, as an imaging console, was highly reliable and was as accurate as PACS workstation for the radiological diagnosis of acute appendicitis.
机译:目的,确定平板电脑作为成像控制台的准确性和可靠性,用于检测急性阑尾炎的放射性迹象[以聚焦的阑尾计算断层扫描(事实)]使用图像归档和通信系统(PACS)工作站作为参考标准。方法从2014年1月到2015年6月,225名患者在我们的机构接受了事实。这些扫描盲目地被独立顾问放射科医生重新解释,首先在PACS工作站,两周后,在平板电脑上。扫描被解释为存在急性阑尾炎的放射症状。使用PACS作为参考标准计算平板电脑的准确性。 Kappa(κ)统计计算为可靠性的衡量标准。结果225例患者,99例对PACS工作站的急性阑尾炎的放射性证据。在检测急性阑尾炎的放射性迹象中,平板电脑100%准确。在90,43,39,10和12次扫描的PACS上鉴定了阑尾溶解,自由流体,淋巴结病,脓肿和穿孔和穿孔。平板电脑和PACS检测阑尾二(кα= 0.924),痰多(к?= 0.904),自由液(к= 0.863),淋巴结病(К?= 0.879)之间,淋巴结病(к?= 0.879)和穿孔(к?= 0.904)。结论平板电脑作为成像控制台,高度可靠,并且与急性阑尾炎的放射学诊断的放射学工作站一样准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号