...
首页> 外文期刊>Abdominal radiology. >Detection of hepatic steatosis and iron content at 3 Tesla: comparison of two-point Dixon, quantitative multi-echo Dixon, and MR spectroscopy
【24h】

Detection of hepatic steatosis and iron content at 3 Tesla: comparison of two-point Dixon, quantitative multi-echo Dixon, and MR spectroscopy

机译:3特斯拉检测肝脏脂肪变性和铁含量:两点迪克森,定量多相迪克森和光谱的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To compare qualitative results obtained from computer-aided dual-ratio analysis on T1-weighted two-point Dixon, with T2*-corrected multi-echo Dixon and T2-corrected multi-echo single-voxel MR spectroscopy sequence (MRS) for evaluation of liver fat and iron at 3T. Methods and materials This retrospective, HIPAA-compliant, IRB-approved study included 479 patients with known or suspected liver disease. Two-point Dixon, multi-echo Dixon, and MR spectroscopy sequences were performed for each patient at 3T. A receiver-operating characteristic analysis was performed to compare the diagnostic performance in 80 patients using biopsy as the standard. Sensitivity, specificity, PPV, and NPV of qualitative two-point Dixon results, multi-echo Dixon (PDFF and R2*), and MRS (fat fraction and R2 water) for detection of hepatic steatosis and siderosis were assessed. Results Fat fractions obtained from MRS and multi-echo Dixon have equivalent accuracy for detection of hepatic steatosis (AUC, sensitivity and specificity: 0.90 vs 0.88, 0.77 vs. 0.82, and 0.90 vs. 0.82), but the optimal cutoff value is higher for MRS (6.05% vs. 3.4%). The dual-ratio Dixon discrimination technique showed high negative predictive value for detection of hepatic steatosis and siderosis (0.90 and 0.94, respectively). R2* from multi-echo Dixon and R2water from MRS have equivalent accuracy for detection of iron overload at 3T (AUC 0.89 vs. 0.88). The optimal cutoff for R2* and R2water are 60.5 s-1 and 40.85 s-1, respectively. Conclusion The computer-aided dual-ratio discrimination with two-point Dixon is a useful qualitative screening tool with high negative predictive value for hepatic steatosis and iron overload. Multi-echo Dixon and MRS have similar accuracy for detection of hepatic steatosis and iron overload at 3 Tesla.
机译:为了比较从T1加权两点Dixon的计算机辅助双重比分析获得的定性结果,用T2 *被判据的多回声Dixon和T2校正的多相单voxel MR光谱序列(MRS)进行评估肝脏脂肪和铁在3T。方法和材料这种回顾性,符合性的IRB批准的研究包括479名已知或疑似肝病。对3T的每位患者进行两点Dixon,多回波Dixon和MR光谱序列。进行接收器操作特征分析以比较80例使用活组织检查作为标准患者的诊断性能。定性两点Dixon结果,多回声迪克森(PDFF和R2 *)的敏感性,特异性,PPV和NPV,以及用于检测肝脏脂肪变性和肺炎的MRS(脂肪分数和R2水)。结果从MRS和多回声Dixon获得的脂肪分数具有检测肝脏脂肪变性的等效精度(AUC,敏感性和特异性:0.90 Vs 0.88,0.77 Vs.0.82和0.90与0.82),但最佳截止值较高太太(6.05%vs.3.4%)。双重比迪克森鉴别技术表现出用于检测肝脏脂肪变性和肺炎(分别为0.90和0.94)的高负预测值。来自MRS的多回声Dixon和R2水的R2 *具有相同的精度,用于检测3T的铁过载(AUC 0.89 Vs. 0.88)。 R2 *和R2水的最佳截止分别为60.5 s-1和40.85 s-1。结论两点迪克松的计算机辅助双重比鉴别是一种有用的定性筛选工具,具有高负预测值,用于肝脏脂肪变性和铁过载。多回声Dixon和MRS具有类似的准确性,用于检测3特斯拉的肝脏脂肪变性和铁过载。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号