首页> 外文期刊>Cryogenics >A simple model for the prediction of quench point in cable-in-conduit conductors
【24h】

A simple model for the prediction of quench point in cable-in-conduit conductors

机译:预测导管中导体淬火点的简单模型

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A simple 0D analytical model for the prediction of the take-off point observed in critical-current or current-sharing tests in cable-in-conduit conductors (CICC) is presented. This may be referred to also as the quench point and defined as the point where the stationary thermal equilibrium between the conductor and helium is lost. Assuming a power-law parameterization for the current voltage characteristic of the superconductor, specified by the index n and voltage criterion E_c, the quench point can be unambiguously defined as the contact point between the heat-generation curve and the cooling curve. The model offers a straightforward approach to estimating the quench behavior of CICC and provides a clear view of the relationships between conductor parameters and its quench properties. The results of the model are close to the experimental results thus validating it as a useful design criterion.
机译:提出了一种简单的0D分析模型,用于预测在导管内导体(CICC)中的临界电流或均流测试中观察到的起飞点。这也可以称为淬火点,并且定义为导体和氦气之间失去稳态热平衡的点。假设由指数n和电压标准E_c指定的超导体当前电压特性的功率定律参数化,可以明确地将淬火点定义为发热曲线和冷却曲线之间的接触点。该模型提供了一种简单的方法来估计CICC的淬火行为,并提供了导体参数与其淬火特性之间关系的清晰视图。该模型的结果接近于实验结果,因此将其验证为有用的设计准则。