Current redistribution and stability of superconducting triplex cable without electrical insulation carrying non-uniform current

机译:超导电三层电缆在没有电绝缘的情况下承载不均匀电流的电流重新分配和稳定性

获取原文
获取原文并翻译 | 示例

摘要

When a small normal zone is produced in a strand in a superconducting cable by a local disturbance, current redistribution occurs and can help the recovery of its superconducting state. This effect of the current redistribution depends on the initial current distribution. In this paper, the initial current distribution in a triplex cable is controlled artificially to study its influence on the stability against local disturbances. A heat pulse is applied to a strand by a carbon paste heater to initiate the quench. Transient current distributions during quench or recovery process are measured by sets of Hall sensors placed at several locations along the cable axis. When the transport current is less than a threshold value, the stability is improved by the current redistribution from the heated strand to the others, even if the initial current distribution is not uniform. This threshold is related to the current margin of the heated strand, rather than to the current margin of the whole cable. Above this threshold current, the MQE against local disturbances is smaller in the cable with the non-uniform current distribution than in the cable with the uniform current distribution, when the total transport current is identical. If the current of the heated strand is identical and above the threshold, the MQE against local disturbances does not depend on the current distribution and agrees with the MQE of the single isolated strand. It means that the quench of one strand leads to the quench of the cable, and that the stability of one strand in the cable is not influenced by interaction with the others.
机译:当通过局部干扰在超导电缆的多股导线中产生小的正常区域时,会发生电流重新分布,并有助于恢复其超导状态。电流重新分配的效果取决于初始电流分配。本文通过人工控制三层电缆的初始电流分布,以研究其对局部干扰稳定性的影响。碳糊加热器将热脉冲施加到钢绞线上以启动淬火。淬火或恢复过程中的瞬态电流分布是通过沿电缆轴放置在多个位置的霍尔传感器组进行测量的。当输送电流小于阈值时,即使初始电流分布不均匀,也可以通过从加热股线到其他股线的电流重新分配来提高稳定性。该阈值与加热的线束的电流裕度有关,而不是与整个电缆的电流裕度有关。高于此阈值电流时,当总传输电流相同时,在电流分布不均匀的电缆中,抗局部干扰的MQE小于在电流分布均匀的电缆中。如果加热的线束的电流相同且高于阈值,则针对局部干扰的MQE不取决于电流分布,并且与单个隔离线束的MQE一致。这意味着一根绞线的淬火会导致电缆的淬火,并且一根绞线在电缆中的稳定性不受与另一根绞线相互作用的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号