首页> 外文期刊>Current Eye Research >Efficacy of Polytetrafluoroethylene/Polylactide-co-glycolide (PTFE/PLGA) Laminate and PTFE/PLGA Laminate Containing Slow-Releasing Thalidomide in Delayed Adjustable Strabismus Surgery in a Rabbit Model
【24h】

Efficacy of Polytetrafluoroethylene/Polylactide-co-glycolide (PTFE/PLGA) Laminate and PTFE/PLGA Laminate Containing Slow-Releasing Thalidomide in Delayed Adjustable Strabismus Surgery in a Rabbit Model

机译:聚四氟乙烯/聚酰胺 - 共乙酰基(PTFE / PLGA)层压板和PTFE / PLGA层压板的疗效含有缓慢释放的沙利度胺,在兔模型中延迟可调节斜视手术

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To evaluate the efficacy of polytetrafluoroethylene/polylactide-co-glycolide (PTFE/PLGA) laminate containing sustained-release thalidomide for delayed adjustable strabismus surgery.Methods: This is a prospective, masked-observer, controlled study using 50 eyes of 25 rabbits. After superior rectus muscle (SRM) recession, a PTFE/PLGA laminate containing thalidomide (group PT, 20 eyes), PTFE/PLGA laminate alone (group P, 20 eyes), or no barrier (group C, 10 eyes) were applied around the SRM. Delayed adjustment was performed at postoperative 3 or 5 weeks. Adjustability, adjustment lengths, adjustment forces, and degrees of adhesion were evaluated.Results: Both groups PT and P showed significantly better adjustability compared to group C at both 3 weeks (100%, 80%, and 0%, respectively) and 5 weeks (100%, 90%, and 0%, respectively). Between groups PT and P, adjustability, adjustment lengths, and forces were not significantly different at 3 and 5 weeks. Group PT showed a significantly lower grade of adhesion between SRM and sclera (SRM/S) compared to group C at both 3 weeks (p = 0.007) and 5 weeks (p = 0.001, respectively). Group P showed no significant difference in adhesion between SRM/S compared to group C at 3 weeks (p= 0.302) but had a lower grade of adhesion after 5 weeks (p = 0.007). There was no significant difference between groups PT and P at 3 weeks (p= 0.143) and 5 weeks (p= 0.716).Conclusions: PTFE/PLGA laminate containing sustained-release thalidomide was effective in reducing adhesion and allowed delayed adjustment in all eyes. However,?PTFE/PLGA laminate alone was also equally?effective in reducing adhesion compared to controls.
机译:目的:评价聚四氟乙烯/聚乳糖酰基 - 共乙酰胺(PTFE / PLGA)层压体的疗效,其含有缓释的沙利度胺用于延迟可调节斜面术。方法:这是一种使用50只兔子50只眼睛的预期,掩盖观测器,受控研究。在上生直肠肌(SRM)衰退后,施加含有沙利度胺(Pt,20只眼)的PTFE / PLGA层压板,单独施加PTFE / PLGA层压体(G10只眼)或没有屏障(C组,10只眼) SRM。延迟调整在术后3或5周进行。评估调节性,调整长度,调节力和粘附程度。结果:与3周(100%,80%和0%)和5周的C组(10%,80%和0%)相比,PT和P均显示显着更好的可调节性(分别为100%,90%和0%)。在组Pt和P组之间,可调节性,调节长度和力在3和5周内没有显着差异。与3周(P = 0.007)和5周(P = 0.001分别)相比,组PT组PT在SRM和SCLERA(SRM / S)之间的粘附性显着较低的粘附性。对于3周(P = 0.302),组P组对SRM / s之间的粘附性没有显着差异(P = 0.302),但在5周后较低的粘合等级(p = 0.007)。在3周(p = 0.143)和5周(p = 0.716)之间,群体Pt和P之间没有显着差异。然而,单独的PTFE / PLGA层压体也同样是αs的同样?与对照相比减少粘附性。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号