首页> 外文期刊>Current Eye Research >A Comparison of different scoring terminations rules for visual acuity testing: from a computer simulation to a clinical study
【24h】

A Comparison of different scoring terminations rules for visual acuity testing: from a computer simulation to a clinical study

机译:不同评分终止规则的视力测试规则的比较:从计算机模拟到临床研究

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To compare four visual acuity (VA) scoring termination rules.Methods: A computer simulation generated 30,000 virtual patients who underwent 10 repetitions for each of four termination rules, on both the Snellen and ETDRS charts (2.4 million tests performed in total). Three termination rules focused on the smallest character row: all characters were correctly identified (100%), one character was incorrectly identified (one miss) and 50% or more of the characters were correctly identified (50%). The forth termination rule used a calculation in which each character, when correctly recognized, contributed a proportional increment (per-letter). Accuracy, test-retest variability (TRV) and test duration were measured. Next, a clinical study was conducted in which 254 subjects underwent three repetitions of the ETDRS VA test from 4 m, and VA scores for each of the four scoring termination rules were calculated.Results: In the Snellen simulation, the mean accuracy of the 100%, one miss, 50% and per-letter termination rules in decimal was 0.23 (?0.16 logMAR), 0.11 (?0.09 logMAR), 0.10 (?0.08 logMAR), and ?0.08 (0.08 logMAR) respectively; while with the ETDRS simulation, the mean accuracy in decimal was 0.34 (?0.22 logMAR), 0.14 (?0.11 logMAR), 0.07 (?0.06 logMAR), and 0.07 (?0.05 logMAR), respectively. For the ETDRS simulation, the per-letter had the lowest TRV values and the longest test duration. In the clinical study (n = 254), the reproducibility of the 100%, one miss, 50% and per-letter was 0.50, 0.53, 0.17, 0.14, respectively.Conclusions: Clinical study and simulation data both suggest that the 100% and one-miss termination rules have higher TRVs, while the 50% and per-letter demonstrated much tighter, and rather close, TRV values.
机译:目的:比较四个视力(VA)得分终止规则。三个终止规则专注于最小字符的行:正确识别所有字符(100%),一个字符被错误识别(一个未命中),正确识别了50%或更多的字符(50%)。 FROTH终止规则使用了一个计算,其中每个字符在正确识别时,贡献比例增量(每字母)。测量精度,测试 - 重度变异性(TRV)和测试持续时间。接下来,进行了临床研究,其中254受试者从4米开始的ETDRS VA试验进行了三次重复,并且计算了四个得分终止规则中的每一个的VA分数。结果:在斯内伦仿真中,100的平均准确性十进制中%,一个未命中,50%和每封信终止规则为0.23(?0.16 logmar),0.11(?0.09 logmar),0.10(?0.08 logmar),分别为0.08(0.08个logmar);虽然具有ETDRS模拟,但小数的平均精度分别为0.34(?0.22 logmar),0.14(?0.11 Logmar),0.07(Δ06logmar)和0.07(?0.05 Logmar)。对于ETDRS仿真,每封信具有最低的TRV值和最长的测试持续时间。在临床研究(n = 254)中,100%,一个未命中,50%和每字母的再现性分别为0.50,0.53,0.17,0.14。结论:临床研究和仿真数据既表明100%一次错误的终止规则具有更高的TRV,而50%和每封信展现得更紧凑,而且相当近距离TRV值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号