Objective. To incorporate a metal framework into removable partial dentures, the dimensional accuracy of thermoplastic resins requires precision equivalent to conventional acrylic resins. This study aimed to evaluate the fitting accuracy of thermoplastic resins compared to heat-cured acrylic resin. Materials and methods. Four thermoplastic resins (polyethylene terephthalate [EstheShot, ES; EstheShot Bright, ES-B], polyamide [Lucitone FRS, LF], polycarbonate [Reigning Resin N, RN] and a heat-curing acrylic resin [Acron, AC]) were used. The specimens were created on master casts constructed of high-strength stone that simulated a maxillary edentulous ridge. Additionally, high-expansion stone was used as the master cast for RN specimens. The ES-B, LF and RN specimens were prepared with and without annealing after injection molding. The gaps between the molded resin and the cast were measured. Results. ES had the smallest gap and was significantly smaller than AC (p < 0.05). The gap sizes of ES-B, LF and RN (high-expansion stone) without annealing were similar to AC (p > 0.05), while the gap size of RN (high-strength stone) with and without annealing was significantly greater than AC (p < 0.001). The gap sizes of ES-B and LF with annealing were significantly less than AC (p < 0.05). Further, the gap sizes of ES-B, LF and RN with annealing were significantly smaller than the gaps without annealing (p < 0.05). Conclusions. The results suggested that ES, ES-B and LF have adequate fitting accuracy for incorporating metal framework into dentures and that annealing effectively improved the fitting accuracy of ES-B, LF and RN.
机译:目的。为了将金属框架结合到可摘局部义齿中,热塑性树脂的尺寸精度要求与常规丙烯酸树脂相当的精度。这项研究旨在评估热塑性树脂与热固化丙烯酸树脂相比的贴合精度。材料和方法。使用了四种热塑性树脂(聚对苯二甲酸乙二醇酯[EstheShot,ES; EstheShot Bright,ES-B],聚酰胺[Lucitone FRS,LF],聚碳酸酯[Reigning Resin N,RN]和热固化丙烯酸树脂[Acron,AC]) 。标本是在由高强度石头构成的主模型上制作的,模拟了上颌无牙的脊。此外,高膨胀石材被用作RN标本的主铸件。 ES-B,LF和RN样品在注塑后有或没有退火的情况下制备。测量模塑树脂和铸件之间的间隙。结果。 ES具有最小的间隙,并且显着小于AC(p <0.05)。未经退火的ES-B,LF和RN(高膨胀石材)的间隙尺寸与AC相似(p> 0.05),而经过退火和未经退火的RN(高强度石材)的间隙尺寸显着大于AC (p <0.001)。经过退火处理后,ES-B和LF的间隙尺寸显着小于AC(p <0.05)。此外,具有退火的ES-B,LF和RN的间隙尺寸明显小于未经退火的间隙(p <0.05)。结论结果表明,ES,ES-B和LF具有足够的将金属骨架结合到义齿中的装配精度,并且退火有效地提高了ES-B,LF和RN的装配精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号