首页> 外文期刊>Acta odontologica Scandinavica. >Micro-shear bond strength of resin cement to dentin after application of desensitizing toothpastes
【24h】

Micro-shear bond strength of resin cement to dentin after application of desensitizing toothpastes

机译:应用脱敏牙膏后树脂水泥与牙本质的微剪切粘结强度

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objectives. The aim of the study was to evaluate the effect of three desensitizing toothpastes on bonding of resin cements to dentin. Materials and methods. The occlusal surfaces of 72 maxillary third molars were ground to obtain flat dentin surfaces and then divided into three groups according to three desensitizing toothpastes used: Sensodyne Rapid Relief (GlaxoSmithKline, SmithKline Beecham Ltd., Slough, UK), Signal Sensitive Expert (Unilever Sanayi ve Ticaret Turk A.S ., Umraniye, Istanbul, Turkey) and Colgate Sensitive Pro-Relief (Colgate Palmolive, New York, NY). Following bonding of the resin cement (Clearfil~(TM) SA Cement, Kuraray Co, Osaka, Japan) to dentin, the specimens were light cured for 40 s with a LED (Elipar S10, 3M Espe, St. Paul, MN). The strength measurements were accomplished with a micro-shear testing machine (Bisco, Schaumburg, IL) at a cross-head speed of 0.5 mm/min until the failure occurs. Failure modes were examined using a stereomicroscope and scanning electron microscope. The data were analyzed with one-way analysis of variance (ANOVA) and Tukey HSD test (a = 0.05). Results and conclusion. ANOVA revealed that the application of desensitizing toothpastes had significant effects on bond strength of the resin cement tested to dentin (p < 0.05). Mixed failures were observed in all of the groups. Clinical significance. The use of a desensitizing toothpaste before cementation might alter the bond strength of adhesively luted restorations.
机译:目标。该研究的目的是评估三种脱敏牙膏对树脂水泥与牙本质粘合的影响。材料和方法。研磨72个上颌第三磨牙的咬合面以获得平坦的牙本质表面,然后根据所用的三种脱敏牙膏将其分为三组:Sensodyne快速舒缓药(GlaxoSmithKline,SmithKline Beecham Ltd.,英国斯劳),Signal Sensitive Expert(Unilever Sanayi) ve Ticaret Turk AS。,Umraniye,土耳其伊斯坦布尔)和高露洁敏感亲救济组织(高露洁·棕榄,纽约,纽约)。将树脂水泥(ClearfilTM SA水泥,日本大阪市Kuraray公司)粘合到牙本质后,用LED(Elipar S10,3M Espe,St。Paul,MN)将样品光固化40 s。用微剪切试验机(Bisco,Schaumburg,IL)以0.5mm / min的十字头速度完成强度测量,直到发生故障。使用立体显微镜和扫描电子显微镜检查失效模式。使用单向方差分析(ANOVA)和Tukey HSD检验(a = 0.05)对数据进行分析。结果和结论。方差分析显示脱敏牙膏的应用对所测试的树脂胶与牙本质的粘结强度具有显着影响(p <0.05)。在所有组中均观察到混合故障。临床意义。在胶结之前使用脱敏牙膏可能会改变粘结的修复体的粘结强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号